Table 6 1000BASE-ZX GBIC specifications (continued)

Type

Specifications

 

 

Distance

70 km

 

 

Receiver Characteristics

 

 

 

Wavelength

1200 to 1550 nm

 

 

Minimum receiver sensitivity

-22 dBm

 

 

Maximum input power

-3 dBm

 

 

Note: When shorter lengths of single-mode fiber cable are used, there is a risk of overloading the receiver. It may be necessary to insert an in-line optical attenuator in the link to prevent overloading, as follows:

Insert a 10 dB in-line optical attenuator between the fiber optic cable plant and the receiving port on the 1000BASE-ZX GBIC, at each end of the link, if the fiber optic cable span is less than 25 km.

Insert a 5 dB in line optical attenuator between the fiber optic cable plant and the receiving port on the 1000BASE-ZX GBIC, at each end of the link, if the fiber optic cable span is less than 50 km.

14

Page 16
Image 16
Nortel Networks CWDM SFP manual 1000BASE-ZX Gbic specifications