GENERATOR FEATURE
Reference 1 - Air Cleaner. Refer to your Honda engine manual for air cleaner care.
Reference 2 - Starting/Stopping Instructions. Reference 3 - Oil Drain Plug. Refer to your Honda
engine manual for oil change recommendations. Reference 4 - Control Panel. See Fig. 3 for details. Reference 5 - Gas Cap with Gauge. The gas cap is
extra large, creating a large hole for refueling. You can monitor the fuel level without removing the cap by using the fuel level indicator built into the gas cap.
Reference 6 -
Reference 7 - Super Silent Muffler. 4 dB less than Honda’s standard muffler.
Reference 8 - Generator Head. The electricity producing part of the generator.
Reference 9 - Battery Box. Warning: Always wear safety glasses when working on or near the battery. The battery box provides protection for the battery and will
accept a standard lawn tractor size battery (Group
WARNING Sulfuric acid is a corrosive poison. Avoid contact with skin, eyes or clothing. Always wear safety glasses.
Reference 10 - Vibration Isolation Mounts. The engine and generator are mounted on rubber cylinders that absorb most of the engine vibration. This feature eliminates the tendency of the machine to “walk” which is common in engine powered equipment.
Reference 11 - Recoil. Grasp firmly when starting engine.
Reference 12 - Gas Line Valve. The engine is
equipped with an
Reference 13 - Choke Lever. Used during cold
starts. Refer to the starting/stopping instructions and the Honda engine manual for usage.
RE CEPTA CLES
IDLE CONTR OL
HOUR METE R
G
H@
H?
Reference 14 - Electric Start/Stop Switch. The
engine key is located on the engine. Always locate this switch and be familiar with its location before operating the generator.
Reference 15 and 16 – Reserved for future use.
CONTROL PANEL IDENTIFICATION
| Figure 3 (Ref. | 01937 |
| ||
|
|
|
|
|
|
| Ref. |
| Description |
|
|
17Full Power Switch
18Voltmeter
19Hour Meter
20
21Grounding Post
22
23
24
25
2620A Circuit Breaker
2730A Circuit Breaker
2850A Circuit Breaker
29Main Line Circuit Breaker 30A
30Idle Control On/Off Switch
Reference 17 - Full Power Switch. The switch
reconnects the two generator windings from parallel (120V only) to series (120/240V).
•120V Only: Allows all 6600 watts (55A) to be used in any combination of 120 volt receptacles. The 120/240V 30A
•120/240V : Allows all 6600 watts to be used for 240V. However, only half the power or 3300 watts (27.5A), can be used at any one 120V receptacle. 120V output
can total 6600 watts.
Reference 18 - Voltmeter. Voltmeter needle should be in green area during all generator load conditions.
Reference 19 - Hour Meter. Allows for better maintenance scheduling of generator.
Reference 20 - 120/240V 30A Receptacle. This
receptacle is a NEMA
Reference 21 - Grounding Post. Ground the generator via the grounding post, to a copper pipe or rod that is driven down until it reaching moist soil.
References 22-25 - 120V Receptacles. The
generator has a control panel with:
•Reference 22 - One NEMA
4