North Star M165951C owner manual Maintenance and Storage, Operation Instructions

Models: M165951C

1 15
Download 15 pages 49.02 Kb
Page 11
Image 11
Maintenance and Storage

Storage – Keep the generator covered and away from any moisture.Manual background Operation Instructions

Use to Approximate Generator Load Requirements

Device

Running Watts

 

Device

Running Watts

Air Conditioner (12,000 Btu)

1700 (a)

 

Lawn Mower

1200

Battery Charger (20 Amp)

500

 

Light Bulb

100

Belt Sander (3”)

1000

 

Microwave Oven

700

Chain Saw

1200

 

Milk Cooler

1100 (a)

Circular Saw (6-1/2”)

900

 

Oil Burner on Furnace

300

Coffee Maker

1000

 

Oil Fired Space Htr (140,000 Btu)

400

Compressor (1 HP)

2000 (a)

 

Oil Fired Space Htr (85,000 Btu)

225

Compressor (3/4 HP)

1800 (a)

 

Oil Fired Space Htr (30,000 Btu)

150

Compressor (1/2 HP)

1400 (a)

 

Oven

4500

Curling Iron

700

 

Paint Sprayer, Airless (1/3 HP)

600 (a)

Dishwasher

1200

 

Paint Sprayer, Airless (handheld)

150

Edge Trimmer

500

 

Radio

200

Electric Nail Gun

1200

 

Refrigerator

600 (b)

Electric Range (one element)

1500

 

Slow Cooker

200

Electric Skillet

1250

 

Submersible Pump (1-1/2 HP)

2800 (a)

Freezer

800 (b)

 

Submersible Pump (1 HP)

2000 (a)

Furnace Fan (1/3 HP)

1200 (a)

 

Submersible Pump (1/2 HP)

1500 (a)

Hair Dryer

1200

 

Sump Pump

600 (a)

Hand Drill (1”)

1100

 

Table Saw (10”)

2000 (a)

Hand Drill (1/2”)

875

 

Television

500

Hand Drill (3/8”)

500

 

Toaster

1000

Hand Drill (1/4”)

250

 

Vacuum cleaner

250

Hedge Trimmer

450

 

VCR

70

Home Computer

150

 

Water Heater

3000

Impact Wrench

500

 

Weed Trimmer

500

Jet Pump

800 (a)

 

 

 

(a)Hard-starting motors require 3 to 5 times the rated running watts.

(b)These loads may require up to 15 minutes to restart due to its normal build up of compressor head pressure. NOTE: For extremely hard to start loads such as air conditioners and air compressors, consult the equipment dealer to determine the maximum wattage.

Maintenance and Storage

The generator head is a two pole, 3600 RPM, 60 Hz, brushless, revolving field and synchronous type with two sealed ball bearings. Proper care and maintenance are required to ensure a long trouble free life. Generator Maintenance - The generator head is brushless and maintenance free. Any major generator service including the installation or replacement of parts should be performed by a qualified electrical

service technician. USE ONLY NorthStar APPROVED REPAIR PARTS AVAILABLE AT 1-800-270-0810.

1.Bearing - The bearings used in this generator are a heavy duty, sealed ball bearing type. They require no maintenance or lubrication.

2.Receptacles - Quality receptacles have been utilized. If a receptacle should become cracked or otherwise damaged, replace it. Using cracked or damaged receptacles can be both dangerous to the operator and destructive to the equipment.

Exercising the Generator - The generator should be operated every four weeks. This is accomplished by running the generator and applying a load for 15 minutes. This will dry out any moisture that has accumulated in the windings. If left, this moisture can cause corrosion in the winding. Frequent operation of the generator will ensure that the generator is operating properly should it be needed in an emergency.

Storage – Keep the generator covered and away from any moisture.

11

Page 11
Image 11
North Star M165951C owner manual Maintenance and Storage, Operation Instructions