4. Select a Suitable Site

Installation / Initial Set-Up

4. Select a Suitable Site

Before using the generator, you must select a suitable OUTDOOR location for installation and operation. This location should meet all of the criteria listed below.

Dry, level surfaceThe generator should be positioned on a dry, firm, level surface. WARNING:

You must choose a suitable site for operating your generator to avoid equipment damage and/or injury and possible death from carbon monoxide poisoning, electric shock, or fire. Choose a site that meets all of the criteria specified.

Dry, level surface

The generator should be positioned on a dry, firm, level surface.

 

Ensure that the generator sits level and will not slide or shift during operation.

Outdoors only –

If applicable, block the generator’s wheels to prevent sliding and shifting.

WARNING: Carbon monoxide poisoning hazard

dangerous carbon

The exhaust from your generator contains carbon monoxide (CO), a

monoxide exhaust

poisonous gas that can kill. You cannot smell it, see it, or taste it.

 

Carbon monoxide exhaust is given off whether you are using gasoline,

 

natural gas, or propane as the fuel source to power the generator.

 

Follow the directions below for choosing a location to operate your

 

generator in order to avoid carbon monoxide poisoning.

The location you choose to operate the generator must be OUTDOORS and away from all air intakes:

Never run the generator inside any closed or semi-enclosed spaces (even if outdoors), including homes, garages, basements, sheds, or boxes. These spaces can trap poisonous gases, even if you run a fan or open windows.

Place the generator so that the exhaust fumes will not be directed towards people or building air intakes.

Ensure that working, battery-operated or battery back-up carbon monoxide alarms are used in any dwelling/structure that is in close proximity to the running generator.

Note that this generator is NOT designed or approved for use in vehicles or marine applications. Never run the generator inside RVs or other vehicles, on boats, or on pick-up truck beds.

 

WARNING:

 

Never attempt to attach ductwork to the muffler system to allow for

 

installation inside an enclosure. This could cause hot air deflection,

 

heat build-up, and increased exhaust back-pressure, resulting in

 

possible exhaust leakage or damage to the generator.

Adequate cooling

The generator needs adequate, unobstructed flow of air to allow for

ventilation

proper cooling of engine and generator head.

 

WARNING:

 

Heat build-up from inadequate ventilation can result in fire, posing a

 

serious risk to nearby persons and structures.

16