Northstar Explorer F210 Installation and Operation Manual 7
Selecting units of measure
The Explorer F210 will indicate fuel values in
Litres, Imperial gallons or US gallons. To change
the current setting perform the follow ing steps:
1. Power up the unit while holding down the
key.
TOTALFLOW

^V

Hold down during power up
2. When the unit is on, release the key. The
display will indicate the current display unit
with:
8U1
Imperial Gallons
8U2
US Gallons
8U3
Litres
3. To select the display unit desired, use the
and keys to change the value.
4. To exit this mode, press and hold both the
and keys simultaneously for one second.
Press and hold to exit
Information will now be indicated in the selec ted
display unit.
Calibration
The fuel transducer supplied with the fuel f low
meter will provide readings at better than 5%
accuracy. Individual calibration will increase this
level of accuracy to better than 2% over a fuel
flow range of 10.0 to 120 litres per hour. Use the
following steps to calibrate your fuel flow m eter:
1. Reset the total log value to zero (see previous
page).
2. Use a known amount of fuel. The larger the
amount the more accurate the calibration will
be.
3. Take note of the actual volume of fuel used
and the fuel used indicated by the total log. If
these two totals are different the instrument
may require calibration.
4. Press and hold the key while applying
power
FLOW

^

Hold down during power up
5. Release the key. Display will flash current
total log value.
260
6. Use the or keys to make the display
indicate the actual volume of fuel used.
7. Press both keys simultaneously for 1 sec to
exit.
Press and hold for 1 second
The fuel flow meter is now calibrated.
2 Instrument Setup