D Logs summary
196 MiLLennium GP SCard Software Version 4.50 Command Descriptions Manual Rev 1Table D-5 Receiver Self-Test Status Codes

N7 N 6 N 5 N 4 N 3 N 2 N 1 N 0 <-

<- Nibble

Number

27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9876543210Bit Des crip tion Range Val ues Hex V alue
lsb
=
0
ANTENNA 1 = good, 0 = bad 00000001
1L1 PLL 1 = good, 0 = bad 00000002
2RAM 1 = good, 0 = bad 00000004
3ROM 1 = good, 0 = bad 00000008
4DSP 1 = good, 0 = bad 00000010
5L1 AGC 1 = good, 0 = bad 00000020
6COM 1 1 = good, 0 = bad 00000040
7COM 2 1 = good, 0 = bad 00000080
8WEEK 1 = not set, 0 = set 00000100
9NO
COARSETIME 1 = not set, 0 = set 00000200
10 NO FINETIME 1 = not set, 0 = set 00000400
11 L1 JAMMER 1 = present, 0 = normal 00000800
12 BUFFER COM 1 1 = overr un, 0 = normal 00001000
13 BUFFER COM 2 1 = overr un, 0 = normal 00002000
14 BUFFER
CONSOLE 1 = overrun, 0 = normal 00004000
15 CPU OVERLOAD 1 = over load, 0 = normal 00008000
16 ALMANAC
SAVED IN NVM 1 = yes, 0 = no 00010000
17 L2 AGC 1 = good, 0 = bad 00020000
18 L2 JAMMER 1 = present, 0 = normal 00040000
19 L2 PLL 1 = good, 0 = bad 00080000
20 OCXO PLL 1 = good, 0 = bad 00100000
21 SAVED ALMA.
NEEDS UPDATE 1 = yes, 0 = no 00200000
22 ALMANAC
INVALID 1 = inva lid, 0 = valid 00400000
23 POSITION
SOLUTION
INVALID
1 = inva lid, 0 = valid 00800000
24 POSITION FIXED 1 = yes, 0 = no 01000000
25 CLOCK MODEL
INVALID 1 = inva lid, 0 = valid 02000000
26 CLOCK
STEERING
DISABLED
1 = disabled, 0 = enabl ed 04000000
27 RESERVED
28-