INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS!

Ceiling Fan-Light

MODEL: 763RLN & 769RL

SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT.

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE,

ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION:

For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

PLANNING DUCTWORK AND WIRING

DUCTWORK

1.Use 4" round duct.

2.Plan to run duct from the fan's discharge opening to the outside. For best fan performance, make duct run as short as possible and use minimum number of elbows.

3.Use optional NuTone ducting accessories as needed (refer to NuTone's catalog for a complete listing of optional accessories).

WIRING

Plan to run 120vAC house wiring (with ground) from a power source, through a standard wall switch or an optional NuTone double FAN/LIGHT switch, to the junction box in the Fan-Light's housing.

INSTALLATION INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE,

ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

B. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.

E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

F. NEVER place a switch where it can be reached from a tub or shower.

Unit consists of the housing, power unit/blower assembly (motor, wheel mounting plate, grille, reflector, lens and duct collar).

WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.

WARNING: To reduce the risk of shock, disconnect power before servicing.

Not for use in kitchens.

Do not install in a ceiling insulated to a value greater than R-40.

For installation in sloped ceilings up to 7/12 pitch.

Ductwork must point up.

FOR BEST RESULTS

For new construction install the housing during the rough-in stage of construction. The blower unit, light and grille should be installed after the finished ceiling is in place.

To install the Exhaust Fan-Light in an existing finished building requires an accessible area (attic or crawl space) above the planned location.

INSTALLATION IN A NEW

CONSTRUCTION SITE

PREPARATION

1.Unplug the power unit.

2.Refer to Figure 1. Remove power unit/blower assembly from the housing. Remove screw and pull power unit assembly tabs out of slots in housing. Set unit aside until needed.

3.Remove one of the wiring knockouts from housing.

MOUNTING THE HOUSING

USING SIDE MOUNTING TABS

Refer to Figure 2.

1.Locate housing next to ceiling joist.

2.Use wood screws (not provided) to loosely attach housing to ceiling joist through keyhole slots in mounting tabs.

3.Adjust housing so that it will be flush with the finished ceiling.

4.When housing is properly adjusted, tighten screws in slots.

USING HANGER BARS

(Hanger bars sold separately, order model HB4) Refer to Figure 3.

1.Insert hanger bars in slots provided in housing.

2.Locate fan housing between ceiling joists so that bottom of fan housing is even with the planned finished ceiling.

3.Use screws or nails to secure mounting brackets to ceiling joists.

INSTALLING DUCTWORK

1.Refer to Figure 1. Place duct collar over flanges at discharge opening of fan. Secure collar by snapping tabs into slots in flanges.

2.Refer to Figure 4. Run 4" round duct from outside to fan's discharge opening.

3.Connect duct to duct collar.

Page 1
Image 1
NuTone important safety instructions Model 763RLN & 769RL

769RL, 763RLN specifications

NuTone has long been a trusted name in home ventilation, and its offerings like the NuTone 769RL and 763RLN ceiling exhaust fans are perfect examples of the company's commitment to quality and innovation. These models are designed to efficiently handle bathroom ventilation while offering added features that enhance user experience and convenience.

One of the standout features of the NuTone 769RL is its sleek, contemporary design. The fan is equipped with a bright, energy-efficient LED light, ensuring that your bathroom is well-lit without straining your electricity bill. The integrated light fixture provides sufficient illumination while contributing to the overall aesthetic appeal of the space. The fan also offers a unique, adjustable lens that allows homeowners to customize the direction and intensity of the light, ensuring optimal visibility wherever needed.

On the other hand, the NuTone 763RLN offers similar features with a brushed nickel finish that adds a touch of elegance to any bathroom decor. This model also includes an energy-efficient LED light and is designed to be compatible with standard home dimmers. The ability to adjust the lighting allows users to create a relaxing ambiance, making this model an ideal choice for those who appreciate flexibility in their living spaces.

Both models boast an impressive noise level, operating at an efficient low sone rating. This ensures a quieter environment, allowing for discreet operation while removing humidity and unpleasant odors from your bathroom. Coupled with their powerful airflow capacity, these fans are capable of ventilating even the largest of bathrooms efficiently.

The NuTone 769RL and 763RLN are equipped with advanced technologies that promote longevity and easy maintenance. Their UL-listed motor ensures reliability, and the housing is designed for easy installation, enabling homeowners to upgrade their ventilation system quickly. The fans also incorporate a dynamic airflow design that reduces the risk of clogged ducts, ensuring continuous performance.

In conclusion, the NuTone 769RL and 763RLN ceiling exhaust fans stand out for their efficient ventilation, elegant designs, and modern technologies. Homeowners looking to enhance their bathroom environments will appreciate the combination of practicality, style, and energy efficiency these models provide. Whether you prioritize aesthetics or functionality, the NuTone series meets and exceeds expectations, making them a worthwhile investment for any home.