NuTone 763RLN Installation In Existing Construction, Planning, Power/Blower Unit Installation

Models: 769RL 763RLN

1 8
Download 8 pages 29.08 Kb
Page 2
Image 2
INSTALLATION IN EXISTING

WIRING

Refer to Figures 5 and 6.

All wiring must comply with local codes and unit must be properly grounded.

1.Run 120vAC house wiring from power source, through wall switch, to junction box in housing.

2.To control both fan and light with one switch, install wiring.

3.For separate control of the fan and light, use NuTone double switch and install wiring.

4.Install approved box connector into wiring access hole. String wires through box connector and into junction box.

5.Use approved wire nuts to make wire connections. Green or bare supply ground lead must be connected to green lead in wiring compartment.

INSTALLATION IN EXISTING

CONSTRUCTION

PLANNING

Installing a bathroom exhaust fan-light in a finished house requires at least a small accessible area (attic or crawl space) above the planned installation location.

Plan ducting and wiring before proceeding with installation (see page 1).

CAUTION: Check area above planned location to be sure that:

(1)Ducting can be installed

(2)Wiring can be run to the planned location

(3)No wiring or other obstruction might interfere with installation

POWER/BLOWER UNIT INSTALLATION

Refer to Figure 1.

1.Place power/blower unit into housing so that mounting plate's tabs insert into slots in housing.

2.Secure mounting plate with provided screw.

3.Insert motor plug into junction box receptacle.

COMPLETING INSTALLATION

Refer to Figure 1.

1.Remove wing nut from the threaded bolt on motor mounting strap.

2.Place reflector into grille.

3.Align grille/reflector assembly with housing and insert light plug into receptacle in junction box.

4.Using wing nut, secure grille/reflector assembly to motor mounting strap.

5.Install 100 watt (maximum) light bulb into light socket.

6.Install lens by squeezing both sides and inserting lens tabs into slots in grille.

INSTALLATION

1.The fan light can be mounted directly to a ceiling joist or spaced between joists using hanger bars (sold separately). If housing is to be mounted directly to ceiling joist plan cutout so side of housing with mounting tabs is against joist.

LOCATING JOIST: Lightly tap the ceiling. A hollow sound means no joists, a solid sound means a joist is present. To be sure you have located a joist, drill a small hole (1/16") and probe into the ceiling with a wire. Leave wire in hole to help locate it in the attic or crawl space.

2.Locate hole in attic or crawl space.

3.Using the housing as a template, mark the ceiling for the cutout. Cutout dimensions: 91/8" x 91/8".

4.Make cutout along marked line.

5.Refer to Mounting The Housing on page 2.

One Year Limited Warranty

WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED

WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.

THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions.

The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.

NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.

WARRANTY SERVICE: To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.

Date of Installation

Builder or Installer

 

 

Model No. and Product Description

 

 

IF YOU NEED ASSISTANCE OR SERVICE:

 

For the location of your nearest NuTone Independent Authorized Service Center:

 

Residents of the contiguous United States Dial Free 1-800-543-8687

 

Please be prepared to provide:

 

Product model number • Date and Proof of purchase • The nature of the difficulty

Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599.

Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9.

Rev. 03/2001

Product specifications subject to change without notice. 4820 Red Bank Road, Cincinnati, Ohio 45227 Printed in U.S.A., Rev. 01/04, Part No. 87538

Page 2
Image 2
NuTone 763RLN Installation In Existing Construction, Planning, Power/Blower Unit Installation, Completing Installation