NuTone 8210 Series important safety instructions Important Safety Instructions, MODEL 8210 SERIES

Models: 8210 Series

1 2
Download 2 pages 38.33 Kb
Page 1
Image 1
7˝ Round Ceiling Fan

READ & SAVE THESE INSTRUCTIONS! INSTALLATION INSTRUCTIONS

7˝ Round Ceiling Fan

MODEL: 8210 SERIES

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally.

When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION:

For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

INSTALLATION INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

B. Sufficient air is needed for proper combusition and exhausting of

gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.

E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

F. NEVER place a switch where it can be reached from a tub or shower.

Do not mount over tub or in shower stall enclosure.

Suitable for use with solid-state speed control.

CAUTION: To reduce risk of fire and to properly exhaust air, be certain the unit is ducted to the outside. Do not vent exhaust air into spaces within walls or ceiling or into attics, crawl spaces or garages.

WARNING: Disconnect power before servicing.

TYPICAL INSTALLATION IN

ROOF CAP

(SOLD SEPARATELY)

EXISTING CONSTRUCTION

 

7" DUCT

 

(PURCHASE LOCALLY)

 

 

ADJUSTABLE

 

MOUNTING

 

BRACKET

 

OUTLET BOX

MODEL 834 FILTER

 

(SOLD SEPARATELY)

 

GRILLE

 

 

GRILLE SCREW

INSTALLATION IN EXISTING CONSTRUCTION

PREPARING THE INSTALLATION SITE

IMPORTANT: 18" minimum clearance space above ceiling is required.

1.Cut 878" diameter opening in ceiling adjacent to ceiling joist. Install header so that housing can be supported on two sides.

If opening cannot be located adjacent to joist, install two headers for proper housing support.

2.Disconnect power at circuit breaker. Run house wiring (with ground) from wall switch to fan location.

IMPORTANT: Be certain all wiring complies with electrical codes and the unit is properly grounded.

Page 1
Image 1
NuTone 8210 Series important safety instructions Important Safety Instructions, Installation Instructions