MOUNTING THE HOUSING
1.Locate housing between joists.
2.Refer to Figure 5. Using nails, secure hanger bars to joists.
NOTE: The hanger bar brackets are adjustable.
Allowing for the thickness of the finished ceiling, mount hanger bars so that edge of housing will be flush with the finished ceiling.
3. Adjust brackets as required. Tighten brackets.
INSTALLING THE DUCTWORK
1.Refer to Figure 5. Install duct collar.
2.Using 4" round duct, connect duct to collar and tape connection.
INSTALLING THE SWITCH
1.Install
2.Refer to Figure 6. Run wiring and make wiring connections.
3.Use supplied screws to secure switch bracket assembly to switch box.
4.Using supplied screws, secure wall plate to switch bracket.
INSTALLING AND CONNECTING THE WIRING
Refer to Figure 6.
All wiring must comply with local codes and unit must be properly grounded.
1.Using
The unit must be wired on a separate 20 Amp circuit.
2.Run wiring from switch location to housing as shown in the wiring diagram.
3.Make wiring connections as shown in wiring diagram.
4.Replace junction box cover. Slide slotted hole in cover over screw. Tighten screw securely.
5.Secure wire cover with one screw.
6.Insert heater and ventilator plugs into proper receptacles as shown.
DUCT COLLAR |
FIGURE 5 |
HEATER |
JUNCTION BOX |
HEATER (WHITE)
WHTRED
VENT
WHTBLU.
T
MOUNTING THE GRILLE ASSEMBLY
1.Refer to Figure 7. Using two screws (provided), secure grille to housing.
SWITCH
BOX
GROUND
VENT
HEAT
WHITE | BLACK |
NOTE:
WHEN THERMOSTAT OR TIMER IS USED, CONNECT AT T
120vAC
LINE
FIGURE 6