READ AND SAVE THESE INSTRUCTIONS

! INTENDED FOR DOMESTIC COOKING ONLY ! WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by a qualified person(s) in accor- dance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equip- ment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.Do not use this unit with any separate solid-state speed control device.

8.To reduce the risk of fire, use only steel ductwork.

9.This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A.Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

B.Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).

C.Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

D.Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

1.SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately,

EVACUATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN - You may be burned.

3.DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result.

4.Use an extinguisher ONLY if:

A.You know you have a Class ABC extinguisher and you already know how to operate it.

B.The fire is small and contained in the area where it started.

C.The fire department is being called.

D.You can fight the fire with your back to an exit.

* Based on “Kitchen Fire Safety Tips” published by NFPA.

2

Page 2
Image 2
NuTone NP503004, NP50000 manual Read and Save These Instructions

NP50000, NP503004 specifications

The NuTone NP503004 and NP50000 models represent a significant advancement in the realm of home ventilation and air quality management. Designed for both residential and commercial use, these models are known for their durability, efficiency, and state-of-the-art features that enhance indoor air quality.

One of the standout features of the NuTone NP503004 is its powerful fan system, which is engineered to deliver high airflow while maintaining low noise levels. This model incorporates an innovative motor technology that allows for efficient operation, saving on energy costs while effectively removing stale air, moisture, and odors from any space. This efficiency is further enhanced by the inclusion of a removable, washable grease filter that ensures a continuous flow of clean air.

In addition, the NP50000 model employs advanced humidity sensing technology. This feature automatically detects increased moisture levels and activates the fan to help prevent mold and mildew accumulation, a prevalent issue in many homes and bathrooms. The ability to control the fan's operation based on real-time conditions enhances both convenience and effectiveness.

Another key characteristic of these NuTone models is their sleek, modern design, which seamlessly integrates into various home aesthetics. The low-profile housing ensures that they do not protrude awkwardly, maintaining an unobtrusive presence while providing superior functionality. Installation is also straightforward, making them suitable for various settings, from newly constructed homes to renovations.

Both models include multiple speed settings, allowing users to customize airflow based on their specific needs. Whether it’s a quick ventilation boost after a shower or steady air circulation in a larger space, these fans offer flexibility that caters to diverse requirements. The NP503004 and NP50000 also feature convenient LED lighting options, providing adequate illumination for various tasks while ensuring energy efficiency.

In summary, the NuTone NP503004 and NP50000 models stand out due to their powerful performance, energy-efficient technologies, advanced humidity sensing, and elegant design. They not only enhance indoor air quality but also add to the aesthetic appeal of any room, making them an excellent choice for homeowners and commercial spaces alike, looking to invest in top-tier ventilation solutions.