| MODELS QTREN080FLT • QTREN110FLT | |
|
|
|
|
|
|
| Page 2 |
TYPICAL INSTALLATIONS |
| PLAN THE INSTALLATION |
HousingmountedtoI-joists.
Housingmountedtojoists. |
Housingmountedanywhere
betweenI-joistsusinghangerbars.
Housingmountedanywhere |
betweenjoistsusinghangerbars. |
| ROOF CAP * |
|
| |
|
|
| ||
DUCT * |
|
|
| |
* Purchase | WALL | |||
CAP | * | |||
ELBOW * | ||||
separately |
|
The unit will operate most quietly and efficiently when lo- cated where the shortest possible duct run and minimum number of elbows will be needed.
Use a roof cap or wall cap that has a
Plan to supply the unit with proper line voltage and appro- priate power cable.
Housingmountedanywhere Housingmountedanywhere betweentrussesusinghangerbars. betweentrussesusinghangerbars.
INSTALL HOUSING & DUCT
1a. Mount |
|
housing to |
|
joist or I- |
|
joist. |
|
Use a pliers to |
|
bend housing |
|
TABS out to | TABS |
900. Hold |
|
housing in |
|
place so that |
|
the housing |
|
tabs contact the | SPACER |
bottom of the | |
joist. The | (use for mounting to |
housing |
|
mounts with |
|
four (4) screws |
|
or nails. Screw |
|
or nail housing |
|
to joist through |
|
lowest holes in |
|
each mounting |
|
flange, then | |
through highest | |
holes. NOTE: |
|
Mounting to
OR