models sSQTXE080 • sSQTXE110
Broan SmartSense® Intelligent Ventilation System Page
read and save these instructions
warning
to reduce the risk of fire, electric shock, or injury to persons, observe the following:
1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including
4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6.This unit must be grounded.
7.Do not connect this product as a load on a fan speed control or light dimmer.
8.Read and understand entire instructions before proceeding with installation.
installation
LINE
Black
|
|
|
| LINE |
|
|
|
| |||
|
|
| Black |
|
|
|
| ||||
POWER | GROUND | GROUND |
|
|
|
|
|
|
| ||
Bare |
| Bare |
|
|
|
| CONTROL | ||||
LINE | Copper | Copper |
|
|
|
| |||||
|
|
|
|
|
|
| |||||
(GFCI |
|
|
|
|
|
|
|
|
| LOAD | |
|
|
|
|
|
|
|
|
| |||
protected |
|
|
|
|
|
|
|
|
| ||
if required) |
|
|
|
|
|
|
|
|
| Red | |
| NEUTRAL |
| NEUTRAL |
|
|
|
| ||||
| White |
| White |
|
|
|
| ||||
|
|
| WHITE |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| BLACK | |
|
| GROUND |
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||||
|
| Green |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| FAN |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
Install controls and wire them as shown. Use following guidelines:
•IMPORTANT:
QTXE080 Ultra Silent™ fan must be wired to SMSC080 SmartSense® control.
QTXE110 Ultra Silent™ fan must be wired to SMSC110 SmartSense® control.
•Use minimum 75 °C rated electrical wiring.
•Except for required neutral wire, these controls install like normal switches. Make sure electrician knows each control location must have a neutral wire. Neutral wire at switch locations may be code requirement or regular practice in installation municipality; but unless explicitly specified, electrician might not install it.
•Specify deep device electrical boxes where controls will be installed. These controls fit in most North American electrical boxes; however, deep boxes provide extra working space which eases installation. Labor cost savings can offset higher box costs, which is usually less than a dollar over standard depth boxes. Use boxes that have 18 cu. in. minimum volume and are at least 1‑1/2 in. deep.
•All controls must be grounded using attached ground wire.