Preventive Measures_________________________

Personal Protective Equipment

Respiratory Protection: Not normally required. For large spills, use dust respirator during cleanup.

Protective Gloves and/or Eye Protection: Not normally required. For large spills, use rubber gloves and safety goggles during cleanup.

Engineering Controls

Ventilation: Outside of normal ventilation, not normally required.

Other Protective Equipment and/or Hygienic Practices: None.

Spill Cleanup

Small Spills

1.Remove sources of ignition.

2.Carefully clean up the spill with a wet cloth, avoiding inhalation of fine dust.

Large Spills

1.Remove sources of ignition and keep unnecessary and unprotected personnel away from area.

2.Wear protective gear: respirator, rubber gloves, safety goggles.

3.Vacuum the spill, then wipe up remainder with a wet cloth.

Waste Disposal

Prevent release of material into natural waters and sewers.

Follow appropriate federal, state and local regulations.

Small amounts can be incinerated.

Careful! Combustion can create harmful gases such as carbon monoxide and nitrogen oxides.

• Large amounts must be passed to a licensed waste contractor.

Precautions

Precautions for Handling or Storage: Protect from the sun. Store in a cool room, under 104°F (40°C). Keep out of reach of children.

Other Precautions: None.

Shipping Information

Special Shipping Information: Non hazardous. Handle container carefully to avoid shock. Do not drop. Keep dry.

User’s Responsibility _________________________

This bulletin cannot cover all possible situations which the user may experience when using this product. Each aspect of your operation must be examined in regard to if, or where, additional precautions may be necessary. All health and safety information contained in this bulletin must be provided to your employees or customers. It is your responsibility to use this information to develop appropriate work practice guidelines and employee instructional programs for your operation.

Preparation Date of MSDS____________________

Date: February 10, 2004.

Prepared by:

Oki Data Americas, Inc

Engineering Services Department.

2000 Bishops Gate Blvd.

Mt. Laurel, NJ 08054-4620

Tel: (856) 235-2600

Fax: (856) 222-5320

http://www.okidata.com

my.okidata.com