Oki BISM2 manual Environmental, Operating temperatures, Storage temperature, Reliability

Models: BISM2

1 34
Download 34 pages 6.14 Kb
Page 28
Image 28

www.ezurio.com

12.4.2FCC and Industry Canada Statements

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

12.4.2.1FCC Labelling requirement

If the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: PI401B” or “Contains FCC ID: PI401B.” Any similar wording that expresses the same meaning may be used.

13. Environmental

13.1Operating temperatures

Parameter

Min

Typ

Max

Operating temp (standard product)

-40

25

+85

 

 

 

 

13.2Storage temperature

Parameter

Min

Max

Unit

 

 

 

 

Storage temp

-40

+125

°C

 

 

 

 

Unit

°C

13.3Reliability

Parameter

Test

Comment

 

 

 

Thermal Shock

200 cycles -40ºC /+85ºC 30 min

1 cycle/hour

 

 

 

Vibration

Continuous operation at 60 Hz,

15g max sine wave, 12 hours

 

2mm stroke

 

 

 

 

Shock

50G 11ms Half Sine Wave

6 axis x 3 cycles each axis

 

 

 

Moisture Resistance

 

 

 

 

 

High Temp Storage

85ºC, 360 hours

 

 

 

 

Low Temp Storage

-40ºC, 240 hours

 

 

 

 

High Temp/Humidity

60ºC, 90%RH, 360 hours

 

Operation

 

 

 

 

 

Thermal shock

-40 to 60ºC in 30min

200 cycles with continuous

 

 

operation

 

 

 

Electro Static Discharge

EN55024:1998 & IEC61000-4-3

 

 

 

 

Drop Test

75cm to concrete, 3 axis x 2

 

 

cycles per corner

 

 

 

 

Page 28
Image 28
Oki BISM2 Environmental, Operating temperatures, Storage temperature, Reliability, FCC and Industry Canada Statements