37
English

Maintenance

Replacing the ADF Pad

After scanning approximately
100,000 pages through the ADF, the
pad module can become worn out
and can cause feeding problems.
Note
One replacement ADF pad is
included with your unit. It is stored
behind a swing-down cover (1) on
the back of the unit:
For additional ADF pads, order
Oki P/N 43103001 (see “Where
to Purchase” on page 31).
1.
Open the ADF cover.
2. Press the white plastic arms on
the sides of the ADF pad inward
and pull the pad out.
3. Press both arms of the new
ADF pad inward. Place the pad
into the holder until it snaps
into place
4. Close the ADF cover.