E-19 E-20

Perform the final checks.

Visual Inspection

After sealing the Case, check the sealing part of front and rear lid
visually to confirm that the O-ring is not twisted or out of the groove
and that no foreign matter has been caught.
:
Hairs, fibers, and other narrow items are not very apparent,
but they may cause entry of water, so that special attention
is required.
CAUTION

Setting the flash power to ON and OFF

Turn the mode dial knob and confirm that the electronic flash can
be turned ON and OFF.
Also turn the mode dial knob and confirm that the flash’s mode dial
can be switched to TTL AUTO and MANUAL.
:
After inserting the flash into the case, confirm that the mode
dial moves. If it does not move, oil or grease may have
gotten on the mode dial. Wipe it clean.
CAUTION
:
Seal the Case by turning both buckle lock levers down in
arrow direction. When one of the buckles is left open, the
Case will not be sealed and water leakage will be caused.
CAUTION

Seal the Case.

When the rear lid is closed
(quietly, so that the O-ring
will not come out of the
groove), the buckles are
engaged with the edge of the
rear lid, and the buckle lock
levers are pushed down in
arrow direction, the Case will
be sealed airtight.

Check the loading status.

Always perform the following final checks before sealing the Case.
Has the electronic flash been inserted properly into the hot shoe of
the case?
Has the silica gel been inserted all the way at the specified
position?
Has the O-ring at the Case opening part been installed properly?
Are the O-ring and the O-ring contact surface on the front lid free of
dirt and other foreign matter?

*PFL-01(E).qxd 03.11.27 3:14 PM ページ E-19 (1,1)