SECTION 13. SPECIFICATIONS (continued)
ALARM OUTPUTS | 2 Form "C" on/off relays. Configurable for latched and  | |
(if applicable)  | unlatched by software.  | |
  | 
  | Max current: 5 AMPS, resistive load  | 
  | 
  | Max voltage: 250 Vac or 30 Vdc  | 
ENVIRONMENT | 
  | |
~ AC units | 115/230 V~(AC) + 10%, 50/60 Hz  | |
  | 
  | 7 W max, power consumption   | 
  | 
  | 8 W max, power consumption (Isolated Analog Out)  | 
  | DC units | |
  | ||
  | 
  | 6 W max, power consumption   | 
  | 
  | 7 W max, power consumption (Isolated Analog Out)  | 
External Fuse Required:  | 
  | ||
  | 
  | 
  | |
  | IEC   | 
  | |
  | 
  | 
  | 
  | 
  | Power  | 
  | Fuse  | 
  | 115 V  | 
  | 125 mA @ 250 (T)  | 
  | 
  | 
  | 
  | 
  | 230 V  | 
  | 63 mA @ 250 (T)  | 
  | UL  | ||
  | 
  | 
  | |
  | Power  | 
  | Fuse  | 
  | 115 V  | 
  | 175 mA @ 250 V   | 
  | 230 V  | 
  | 80 mA @ 250 V   | 
  | 
  | 
  | 
  | 
ENVIRONMENT  | 
  | 
Operating temperature:  | 0° to 50°C (32° to 122°F)  | 
  | (115/230 V rms + 10%)  | 
Storage temperature:  | |
Relative humidity:  | 90% at 40°C   | 
MECHANICAL | 
  | 
Panel cutout:  | 1/8 DIN 3.62 x 1.78" (45 x 92mm)  | 
Weight:  | 1.27 lb (575 g)  | 
Case material:  | Polycarbonate, 94   | 
Protection:  | 