Measurement

Display appears by pressing the [ON-OFF] key after the unit has been ready for measurement.

The power supply turns off automatically about 3 minutes after the last key operation has been finished. For canceling the auto off function, press [ON-OFF] key together with the [CLEAR] key when the power supply is turned off. In this case, a confirmation chime sounds three times.

After several seconds, the sensor number is displayed as shown in (2).

(Note) The display number may change from 01 to 09 according to the kinds of sensor, etc. However, it does not affect any measurement at all.

After several seconds, a measured temperature value is indicated in the upper column, while a measured humidity value is indicated in the lower column as shown in (3).

The initial value of the humidity unit shows a relative humidity. It changes in the order of %RH (relative humidity) → ˚ C (˚ F) (dew point) → ˚ C (˚ F)flickering (wet-bulb temperature) → %RH → ...

(4)shows an example of the dew point indication, while (5) shows an example of the wet-bulb temperature indication. This display turns to %RH indication when pressing the [CLEAR] key.

For finishing the measurement, press [ON-OFF] key. The power off function is set automatically when turning on the power supply next.

KEY OPERATION METHOD WHEN THE UNIT IS

PROVIDED WITH A MEMORY FUNCTION

Data Collection

1. Present time setting

Display flickers when pressing [WRITE] key.

[Year] flickers when pressing [READ] key and it advances stepwise, each time [READ] key is pressed once.

When a desired [Year] has been displayed, press the [WRITE] key to define the year.

For [Month], [Day], [Hour], and [Minute], press [READ] key until they reach a desired value respectively and press [WRITE] key to define them.

By pressing [CLEAR] key, the setting returns to the last one.

2.Setting of the data collection start time Set the data collection start time.

After setting the present time, display flickers.

[Year] flickers when pressing [READ] key and it advances stepwise, each time [READ] key is pressed once.

When a desired [Year] has been displayed, press the [WRITE] key to define the year.

For [Month], [Day], [Hour], and [Minute], press [READ] key until they reach a desired value respectively and press [WRITE] key to define them.

By pressing [CLEAR] key, the setting returns to the last one. Set the reservation time ahead from the present time without fail.

3. Collection and stop

When the reservation time has been set, the confirmation chime sounds. After about 3 minutes, the display appears, and the data collection is started from the reservation time.

For stopping the data collection, press [ON-OFF] key to display the measured value, and then, press the [CLEAR] key.

When the data collection start time has already been set, data collection is executed at the preset time even if the power supply is turned off.

4. Memory

Data can be collected by [temperature, humidity] x 1500.

Data collection is stopped when the memory capacity is fully filled with data. The measuring interval is fixed to 10 minutes.

If data collection was interrupted halfway, past data are valid, but subsequent old data become invalid. (Preset 1000 data are valid, but the 500 data collected last become invalid.)

4.2 RS232 Communications

DATA READ

1. Connection to personal computer

Prepare an NEC PC98 series personal computer.

Connect RH31 to the personal computer by using the attached cable. Attached RS-232C cable

Personal computer

2. Setting of personal computer

Set RS-232C of the personal computer as follows.

Transfer speed: 1200 bps

Character length: 7 bits Parity: None

Stop bit: 2 bits X parameter: None

3. Data read and stop

Data are transmitted to the personal computer by pressing the [READ] key.

In this case, data are transmitted in the units of humidity selected by [SEL] key. Data read is stopped by pressing [CLEAR] key.

Read data (text format) are as shown below

Specify the delimiters of data by comma [,], and use the table calculation soft- ware (EXCEL, Lotus123, etc. for example). Measured values are described on the

cell numerically.

 

a. Collection interval

b. number

c. Temperature

d. Humidity

e. Measurement start year, month, day, and hour %RH: Relative humidity C(F): Dew point $C($F): Wet-bulb temperature

7

8

Page 10
Image 10
Omega M3185/1098 manual RS232 Communications, Measurement, Data Collection, Data Read

M3185/1098 specifications

The Omega M3185/1098 is a sophisticated and highly regarded timepiece that showcases the perfect blend of traditional Swiss watchmaking craftsmanship and modern technology. Designed to cater to both watch enthusiasts and professionals, the M3185/1098 is revered for its precision, reliability, and aesthetic appeal.

At the heart of the Omega M3185/1098 is the exceptional Caliber 3185 movement. This Swiss automatic movement is renowned for its accuracy, boasting a remarkable chronometer certification from the Swiss Official Chronometer Testing Institute (COSC). With a power reserve of approximately 48 hours, the Caliber 3185 ensures that the watch remains functional and precise even after being worn for an extended period. Additionally, this movement features a date function that is easily adjustable, adding to the watch's practicality.

Incorporating advanced technologies, the Omega M3185/1098 features the innovative Co-Axial escapement. This revolutionary component reduces friction between the moving parts of the watch, which ultimately results in improved accuracy and longevity. The Co-Axial escapement minimizes the need for regular servicing, making it a favorite among adventurers and everyday users who appreciate low-maintenance yet reliable timepieces.

The design of the Omega M3185/1098 reflects a harmonious balance between elegance and sportiness. It typically features a stainless steel case that is both durable and lightweight, ensuring comfort during wear. The watch face is often adorned with luminous hour markers and hands, enhancing visibility in low-light conditions. This is complemented by a scratch-resistant sapphire crystal that protects the dial from potential damage.

Water resistance is a key feature of the M3185/1098, making it suitable for various activities, from swimming to snorkeling. With a water resistance rating of up to 300 meters, wearers can confidently engage in aquatic adventures without fearing damage to the movement.

In summary, the Omega M3185/1098 stands out as a remarkable timepiece, showcasing an impeccable blend of state-of-the-art technology and timeless design principles. The combination of the Co-Axial escapement, Caliber 3185 movement, and robust construction make it an ideal choice for anyone seeking a watch that exemplifies both style and functionality. Whether worn in a professional setting or during leisure activities, the M3185/1098 remains a testament to Omega's commitment to excellence in horology.