OM-USB-1208FS User's Guide

Specifications

Note 1: Input current is a function of applied voltage on the analog input channels. For a given input voltage, Vin, the input leakage is approximately equal to (8.181*Vin-12) µA.

Note 2: Maximum throughput scanning to PC memory is machine dependent. The rates specified are for Windows XP only. Maximum rates on operating systems that predate XP may be less and must be determined through testing on your machine

Note 3:

The AD7870 converter only returns 11-bits (0-2047 codes) in single-ended mode.

 

 

 

Table 2. Accuracy, differential mode

 

 

 

 

 

 

 

 

 

Range

 

 

 

Accuracy (LSB)

 

 

 

 

 

 

 

 

 

 

±20 V

 

 

5.1

 

 

±10 V

 

 

6.1

 

 

 

 

 

 

 

 

 

 

±5 V

 

 

8.1

 

 

 

 

 

 

 

 

 

 

±4 V

 

 

9.1

 

 

 

 

 

 

 

 

 

 

±2.5 V

 

 

12.1

 

 

 

 

 

 

 

 

 

 

±2 V

 

 

14.1

 

 

 

 

 

 

 

 

 

 

±1.25 V

 

 

20.1

 

 

 

 

 

 

 

 

 

 

±1 V

 

 

24.1

 

 

 

 

 

Table 3. Accuracy, single-ended mode

 

 

 

 

 

 

 

 

 

Range

 

 

 

Accuracy (LSB)

 

 

 

 

 

 

 

 

 

±10 V

 

 

4.0

 

 

 

 

Table 4. Accuracy components, differential mode - All values are (±)

 

 

 

 

 

 

 

 

Range

 

% of Reading

 

 

Gain Error at full scale (FS)

Offset (mV)

Accuracy at FS (mV)

 

 

 

 

 

(millivolts (mV))

 

 

 

 

 

 

 

 

 

±20 V

 

0.2

 

40

9.766

49.766

±10 V

 

0.2

 

20

9.766

29.766

±5 V

 

0.2

 

10

9.766

19.766

 

 

 

 

 

 

 

±4 V

 

0.2

 

8

9.766

17.766

 

 

 

 

 

 

 

±2.5 V

 

0.2

 

5

9.766

14.766

 

 

 

 

 

 

 

±2 V

 

0.2

 

4

9.766

13.766

 

 

 

 

 

 

 

±1.25 V

 

0.2

 

2.5

9.766

12.266

 

 

 

 

 

 

 

±1 V

 

0.2

 

2

9.766

11.766

 

 

 

 

 

 

 

 

Table 5. Accuracy components, single-ended mode - All values are (±)

 

 

 

 

 

 

 

 

Range

 

% of Reading

 

 

Gain Error at FS (mV)

Offset (mV)

Accuracy at FS (mV)

 

 

 

 

 

 

 

±10 V

 

0.2

 

20

19.531

39.531

 

 

 

 

 

 

 

 

 

 

Table 6. Noise performance, differential mode

 

 

 

 

 

 

 

 

Range

 

Typical counts

 

 

Least significant bitroot mean square (LSBrms)

 

 

 

 

 

 

 

 

±20 V

 

2

 

0.30

 

 

 

 

 

 

 

 

 

±10 V

 

2

 

0.30

 

 

 

 

 

 

 

 

 

±5 V

 

3

 

0.45

 

 

±4 V

 

3

 

0.45

 

 

±2.5 V

 

4

 

0.61

 

 

 

 

 

 

 

 

 

±2 V

 

5

 

0.76

 

 

 

 

 

 

 

 

 

±1.25 V

 

7

 

1.06

 

 

 

 

 

 

 

 

 

±1 V

 

8

 

1.21

 

 

 

 

 

 

 

 

 

 

23

Page 23
Image 23
Omega OM-USB-1208FS manual Range Accuracy LSB

OM-USB-1208FS specifications

The Omega OM-USB-1208FS is a high-performance data acquisition device designed for engineers and technicians who require accurate data logging and analysis in their experiments and applications. This versatile device is equipped with a range of features that make it an ideal choice for various measurement tasks across different industries.

One of the standout features of the OM-USB-1208FS is its ability to support a wide variety of input signals. The device is equipped with 16 analog input channels, which can be used for both voltage and thermocouple inputs, making it suitable for temperature monitoring and other signal measurements. The analog inputs provide a resolution of 16 bits, ensuring precise and reliable readings. Furthermore, it supports sampling rates of up to 100 kS/s, allowing for rapid data acquisition and real-time monitoring.

In addition to its analog capabilities, the OM-USB-1208FS has digital I/O lines that facilitate control and automation tasks. With 8 digital input/output channels, users can easily manage various external devices, sensors, or actuators, enhancing the overall functionality of the data acquisition system. This makes the device suitable for automation projects, as users can trigger actions based on acquired data.

Another distinguishing feature is the built-in USB interface, which offers a straightforward connection to computers without the need for additional power supplies or complex setups. The device is fully compatible with various operating systems, including Windows, making it easy to integrate into existing systems. The included software allows for easy data logging, visualization, and analysis, simplifying the process for users.

The OM-USB-1208FS is designed with durability and reliability in mind. Its compact and rugged construction ensures that it can withstand the rigors of fieldwork and laboratory use. Moreover, the device's comprehensive range of input types and robust performance specifications make it an asset for researchers across diverse fields, including environmental monitoring, manufacturing, and academic research.

In summary, the Omega OM-USB-1208FS is a powerful data acquisition solution that combines a multitude of features and technologies. With its high-resolution analog inputs, digital I/O capabilities, user-friendly USB interface, and reliable construction, it caters to the diverse needs of professionals seeking to capture and analyze data accurately and efficiently. Whether for academic research, industrial applications, or environmental monitoring, the OM-USB-1208FS stands out as a top choice in the data acquisition landscape.