DIN-191 & DIN-192 USERS MANUAL 4

S P E C I F I C A T I O N S

Max common mode voltage: 500Vrms, 60s duration.

Baud rates: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 (Dip -switch selectable). Temperature range (operating & storage): -25 to +70°C. Relative humidity: 0 - 95% noncondensing.

Warranty: 12 months on workmanship and materials.

Power Specifications

Power requirements: Regulated +5Vdc.

Power consumption: 1.0W Max (RS-485 driver on).

MECHANICALS AND DIMENSIONS

Case: ABS case with screw terminal barrier plug (supplied.

RS-485 Connectors: Phoenix screw terminal barrier plug (supplied). Replace with Phoenix MSTB 2.5/4 ST 5.08 or equivalent. Warranty: 12 months on workmanship and materials.

DIN - 191 CONNECTORS

The DIN-191 contains two connectors: a four-pin screw terminal plug and a female DB-9 RS-232 connector.

The four -pin screw terminal plug pin designations are located on the label of each module. The screw terminals will accept up to #14 gauge wire (AWG). This connector is used for +5.0Vdc regulated power supply input and the RS-485 data lines.

Page 5
Image 5
Omega Engineering DIN-190 manual Specification S, Mechanicals and Dimensions, DIN 191 Connectors