Omega Engineering DRN-PS-750 manual Temperature Derating

Models: DRN-PS-750

1 18
Download 18 pages 940 b
Page 13
Image 13

SPECIFICATIONS 5

5.10 Temperature Derating

None below 50 degrees C

DRNÐPSÐ750, 15mA per degree C above 50¡C

5.11 Power-on Indicator

Front Panel red LED lamp

5.12 Short-circuit and overload protection

DRNÐPSÐ750 foldback current limiting with automatic high temperature shutdown

no fuses required

5.13 Wire Connections

Screw down wire clamps, AWG 12 to 26 (ferrules recommended for stranded wire).

DRN-PS Ñ DIN Rail Power Supplies

11