RECALIBRATION: External 14" nut reset screw
OVERRANGE PROTECTION:
50% up to 500°F
MATERIALS:
CONSTRUCTION: Stainless steel welded construction (rust and
corrosion-proof, leakproof, hermetically sealed)
PRESSURE RATING: Rated to 1,000 PSI. Use of thermowell is
recommended for higher pressures or for
very heavy-duty applications.
HEAD & BEZEL: Polished Type 302 stainless steel
MOUNTING: 12"-14 NPT, Type 303 stainless steel, 58" wrench flats.
DIAL FACE: Anodized aluminum. Black marks and numbers
with stain matte finish background. Easy to read.
Minimum parallax.
STEM: Type 304 stainless steel (highly resistant to
corrosion)
CRYSTAL: Optically clear strong glass.
OPTIONAL: Unbreakable clear plastic (not recommended for
ranges over 300°F)
DIMENSIONS:
HEAD DIAMETER: 5" dia.
STEM DIAMETER: 14" dia.
STEM LENGTH: standard is 212 " or 6". Also available: 4", 9", 12",
15", 18", 24", 30", 36". NOTE: A 4" stem is the
shortest length for ranges 0-100°F, 25-125°F, and
0-50°C.
POINTED STEMS: Optional on all models -excellent for probing
asphalt, compost, soil, frozen foods, and other
semi-solid materials.
RESET SCREW: 14" hex nut with slot for screwdriver.
OPTIONAL FEATURES: 12 ", 34" NPT Adaptor Bushing (other threads
available on special order)
Figure 1. Dimensions Model J
C STEM
L
77.0
(3.03)
ROTATE
TILT
.72
(18.3)
39.6 (1.56)
19.1 (.75)
HEAD SIZE 76.2 OR 127
(3 OR 5)
STEM LENGTH
36.3 (1.43)
15.7 (.62)
12.7 (.50)
6.4 (.25)
1/2-14 NPT
15.7 (.62)
(WRENCH FLATS)
RESET
SCREW
5.1 (.20)