VA Series Vapor Actuated Dial Thermometer

Specifications

Dial Sixes:

2", 2 12", 3 12", 4 12"

Dial:

Aluminum with white finish and black markings

Pointer:

Furnished standard adjustable

Movement:

Brass with precision gearing

Bourdon Tube:

Phosphor bronze

Accuracy:

Plus or minus one scale division

Case:

Stainless steel on all front flange and U-clamp models.

 

Back flange models in stainless (2"), black steel (3 12")

 

or Valox (4 12")

Process

Plain bulb, 12" NPT Union, 12" NPT sliding union

Connection:

on 12 Connection: bendable extension, or thermowell.

Window:

Polycarbonate. Glass in 3 12" and 4 12" back flange

 

models

Bulb:

Stainless steel or nickel plated copper. Bulb O.D. 716"

 

(optional 14" O.D. x 2" length on -40 to 65°F range

 

only). Bulb lengths vary from 2" to 6" depending on

 

capillary length

Capillary:

Nickel plated copper, copper with bronze braid

 

armor, stainless steel, stainless steel with stainless

 

steel armor. Capillary lengths 1 to 100 feet (standard

 

length 5 feet)

Ranges:

Over twenty °F and °F/°C ranges available, from -40°

 

to +450°F

Applications:

Control panels, chemical processing, pipelines, food

 

processing, OEM applications, ovens, solar heating,

Vapor actuated thermometers give excellent readings when the bulb temperature is either above or below the temperature of the indicating head. Avoid applications in which the bulb and head are the same temperature (ambient applications). If the bulb “crosses ambient” (i.e., goes from hotter than the indicating