![2.2 Run InstaCalTM](/images/new-backgrounds/134273/1342739x1.webp)
2.2 Run InstaCalTM
To run InstaCalTM in the various forms of Windows, find the file named InstaCal.exe using your file management system and double click your mouse on it. In DOS simply type instacal and press the Enter key.
Once running, InstaCalTM provides four
1.Select Install (either highlight it and hit enter of double click your mouse on it).
2.Select Board #0 (select another number if Board #0 is already installed)
3.Select Board Type
4.Move through the selections and highlight the particular board you are installing (e.g.
Either double click on the board or hit enter.
5.The board’s default settings are then displayed. The board’s defaults are:
BASE ADDRESS: | 300H (768 Decimal) |
WAIT STATE | OFF |
6.You are now ready to install the board in your computer. Open your PC (after turning off the power) and install the board. After the board is installed and the computer is closed up, turn the power back on.
7.Run InstaCalTM again, and at the main menu select Test.
a.Select the board you just installed
b.Select Internal Test
c.The internal control registers of the board will then be tested. If this test is successful, your board is installed correctly. If not, you likely have
a base address conflict, or have the base address switch set incorrectly. Please refer to the next chapter for more information regarding selecting and setting the base address.
d.If the Internal Test is completed successfully, you may want to check that the I/O pins are working correctly. To check this select External Test and follow the instruction provided. This will require the use of an ohmmeter.
6 SPECIFICATIONS
6.1 CIO-RELAY08, 16, 24 and 32 (standard versions)
POWER CONSUMPTION
+5V supply510 mA typical plus 22 mA per active (on) relay
GENERAL SPECIFICATIONS |
|
Number | 8, 16, 24, or 32 |
Contact arrangement | Form C (SPDT) |
Contact rating | 3A @ 120V A.C or 28V D.C. resistive |
Contact type | Gold overlay silver |
Contact resistance | 100 milliohms max. |
Operate time | 20 milliseconds |
Release time | 10 milliseconds max. |
Life expectancy | 10 million mechanical operations min. |
ENVIRONMENTAL |
|
Vibration | 10 to 55 Hz (Dual amplitude 1.5mm) |
Shock | 10G (11 milliseconds) |
Dielectric isolation | 500V (1 minute) |
Life Expectancy | 1 Million Operations Electrical |
| 100,000 Operations @ Full Load |
3 | 12 |