An O M EG A Technologies Com pany

FAR-1 Series

Power Supply (10V, 250MA)

INSTRUCTION

SHEET

M2301/0197

Unpacking Instructions

Remove the Packing List and verify that you have received all equipment, including the following (quantities in parentheses):

FAR-1 Series Power Supply (1)

Instruction Sheet (1)

If you have any questions about the shipment, please call the OMEGA Customer Service Department.

When you receive the shipment, inspect the container and equipment for signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent.

NOTE

The carrier will not honor damage claimsunleesallshippingmaterial is saved for inspection. After examining and removing contents, save packing material and carton in the event reshipment is necessary.

Description

Specially designed to power up to four bridges (load cells of 350Ω ) in parallel at 10Vdc. This unit used whith the CCT-80 signal conditioner accommodates 6-wire bridge circuits, where two wires provide bridge excitation, two wires sense the excitation at the bridge and the other two wires give the signal to the converter. The sensed data is used to compensate errors due to the lead resistance. If a 4-wire load cell is used, then connect terminal 5 to 6 and terminal 3 to 4.

Wiring

 

 

 

 

 

 

 

 

 

+

 

 

 

 

-

LOAD

+

 

 

CELL

 

 

 

 

-

 

 

 

 

 

 

 

 

+

SIGNAL

POWER SUPPLY

 

 

 

-

 

 

 

 

 

+

 

 

 

 

 

 

- Vref

1

2

3

4

5

6

 

~

~

_

_

+

+

 

 

AC

SENSE OUT SENSE

 

 

 

OUT

 

 

 

 

VOLTAGE

 

 

 

 

 

 

 

OUTPUT /

 

 

 

 

 

SALIDA

 

 

 

 

POWER SUPPLY

 

 

 

 

FUENTE

 

 

 

 

 

ALIMENTACION

 

 

 

Figure 1. Wiring Diagram

CJS0895JACB

Page 1
Image 1
Omega Speaker Systems FAR-1 Series instruction sheet Description, Wiring