Card Setup
To double these rates up to a maximum rate of 230.4K bps place the jumper in the divide by 2
DIV4
DIV2
DIV1
Figure 2 - Clocking Mode 'Divide By 2’
Baud Rates and Divisors for the ‘DIV2’ mode
The following table shows some common data rates and the rates you should choose if using the adapter in the ‘DIV2’ mode.
For this Data Rate | Choose this Data Rate |
1200 bps | 600 bps |
2400 bps | 1200 bps |
4800 bps | 2400bps |
9600 bps | 4800 bps |
19.2K bps | 9600 bps |
38.4K bps | 19.2K bps |
57.6 K bps | 28.8K bps |
115.2 K bps | 57.6 K bps |
230.4 K bps | 115.2 K bps |
If your communications package allows the use of Baud rate divisors, choose the appropriate divisor from the following table:
For this Data Rate | Choose this Divisor |
1200 bps | 192 |
2400 bps | 96 |
4800 bps | 48 |
9600 bps | 24 |
19.2K bps | 12 |
38.4K bps | 8 |
57.6K bps | 4 |
115.2K bps | 2 |
230.4K bps | 1 |
Omega Engineering COMM+232.PCI | Page 3 |