iConverter 10FL/T User Manual

iConverter 10FL/T Dual Fiber Modules

Fiber Type

Distance

 

Connector Type

 

 

 

 

 

ST

SC

MT-RJ

LC

 

 

 

 

 

 

 

 

MM

2 km

8300-0

8302-0

-

-

MM

5 km

8300-1

-

8304-1

-

SM

30 km

8301-1

8303-1

8305-1

8307-1

SM

60 km

8301-2

8303-2

-

8307-2

SM

120 km

-

8303-3

-

8307-3

 

iConverter 10FL/T Single-Fiber Modules

 

 

 

 

 

 

 

Fiber /

 

Tx: 1310 nm,

Tx: 1550 nm,

Connector

Distance

Rx: 1550 nm

Rx: 1310 nm

Type

 

 

 

 

 

 

SM / SC

20 km

8310-1

8311-1

 

 

 

 

 

 

SM / SC

40 km

8310-2

8311-2

 

 

 

 

 

 

For wide temperature (-40 to 60º C) modules, add a "W" to the end of the model number. Consult factory for other configurations and extended temperature(-40 to +75º C) modules.

When using single-fiber (SF) media converter models, the Tx wavelength on one end has to match the Rx wavelength on the other.

10FL/T SPECIFICATIONS:

Model Type

10FL/T

Protocols

10BASE-FL, 10 BASE-T

UTP

RJ-45

Connectors

 

 

Fiber

SC, ST, LC, MT-RJ,

Connectors

Single-Fiber SC

Controls

LS/LP, RFD

LED Displays

Power, F/O Link, UTP Link

Dimensions

W:0.85" x D:4.5" x H:2.8"

Weight

8 oz.

 

 

Compliance

UL, CE, FCC Class A,

NEBS Level 3

 

Power

0.5A @ 3.3VDC (typical)

Requirement

 

 

Temperature

Standard:

0 to 50º C

Wide:

-40 to 60º C

 

Storage:

-40 to 80º C

Humidity

5 to 95% (non-condensing)

Altitude

-100m to 4000m

MTBF (hrs)

830,000

ABOUT THIS MANUAL:

This document supports revision “xx/20” of the iConverter 10FL/T. Please refer to the serial number label on the ROM chip of the 10FL/T for the revision number of your product. This revision incorporates the following improvements to the 10FL/T.

1. Link Propagate is the default link mode.

OVERVIEW:

The iConverter 10FL/T converters support the IEEE 802.3 Ethernet standard and convert 10BASE-T unshielded twisted pair (UTP) to 10BASE-FL fiber optic cabling. Mod- els are available for multimode (MM) and single-mode (SM) dual fiber and single-mode single-fiber.

The 10FL/T supports Half-Duplex and Full-Duplex modes and features a crossover UTP switch for easy attachment to hubs, switches and workstations.

The 10FL/T can be used in an unmanaged or managed fashion. When unmanaged, the 10FL/T can be installed in a chassis without a Network Management Module (NMM). To be managed, a NMM module must be installed in the same chassis.

LINK MODES:

In order to accommodate different user needs, the 10FL/T supports two different linking modes.

In Link Propagate (LP), sometimes referred to as “Link Loss Carry Forward”, a converter port transmits a Link signal only when receiving a Link at its other port. For example, the UTP transmits a Link only when receiving a Link at the fiber port [Fig 1(b)]. Link propagate is the factory default setting.

Page 2

Notes:

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

In Remote Fault Detection (RFD), the UTP port transmits a Link signal only when receiving a Link at the fiber port. The fiber port transmits a Link only when receiving Link signals both at the fiber port and the UTP port. As a result, fiber faults (no “Link” received at the fiber) are looped-back and can be reported to the network’s core [Fig 1(c)].

 

 

 

 

 

LP

Fiber

 

LP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UTP

 

 

 

Fiber

 

 

 

 

UTP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch 1

 

Converter A

Converter B

Switch 2

 

 

 

 

 

LP

 

 

LP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch 1

 

Converter A

Converter B

Switch 2

 

 

 

 

 

LP

 

 

RFD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch 1

 

Converter A

Converter B

Switch 2

 

LED On

LED Off

 

 

LED status depends on connected device

Off if device is AN, On if device is Manual

Fig. 1 Link Modes

Page 3

Warning

The operating description in this Instruction Manual is for use by qualified personnel only. To avoid electrical shock, do not perform any servicing of this unit other than that contained in the operating instructions, unless you are qualified and certified to do so by Omnitron Systems Technology, Inc.

Warranty

This product is warranted to the original purchaser against defects in material and workmanship for a period of 2 YEARS from the date of shipment. A LIFETIME limited warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment. To register, complete and mail or fax the enclosed Registration Card to the indicated address. You may also register your product on the internet at www.omnitron-systems.com/Register. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective.

For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s designated US address (within the 48 contiguous states and the District of Columbia) using Omnitron’s standard shipping method.

FRONT PANEL DIP-SWITCH SETTINGS:

Fig. 2 DIP-Switches

REMOTE FAULT DETECT “R/FLT DET” DIP-SWITCH:

When the Remote Fault Detect DIP-Switch is in the “R/Flt Det” position, the Remote Fault Detect mode is enabled. When in the “Norm” (factory setting) position, Remote Fault Detect is disabled and Link Propagate is enabled.

Note that connecting two converters when both are set to RFD mode is illegal and will cause a “deadly embrace” lockup.

RJ45 Crossover “X / =” Switch (Not Shown):

When connecting the UTP port to a hub or switch, set switch to Straight-Through “=” (factory setting). When connecting to a workstation, set it to Crossover “X”.

LED INDICATORS:

 

LED

Color

Description

Pwr:

Yellow

On-Power on

Lk/Act (F/O):

Green

On-Link; Blink-Activity

Lk/Act (UTP):

Green

On-Link; Blink-Activity

MOUNTING AND CABLE ATTACHMENT:

The iConverter modules are hot-swappable and can be installed into any iConverter chassis.

1.Using the chassis’ module guides for alignment, insert the module into the selected slot and secure using the front panel fastener screw.

Page 4

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting from improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer-supplied interfacing, unauthorized modifications or tampering with equipment (including repairs of equipment by personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the environmental specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or maintenance.

No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose.

Exclusive Remedies

The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory.

2.Attach the UTP port to a 10BASE-T Ethernet device using a Category 5 cable. If the attached device features 10/100 or 10/100/1000 Auto-Negotiation, disable this feature and manually set the UTP port speed of the connected device to 10Mbps.

3.Using a multimode or single-mode dual-fiber cable as required per the converter type, attach the fiber port to a 10BASE-FL mating Ethernet device. The transmit (Tx) must attach to the receive side of the mating device and the receive (Rx) must attach to the transmit side.

4.Single-fiber (SF) converters must be used in matched pairs. The transmit (Tx) and receive (Rx) wavelengths of one converter must match the receive (Rx) and transmit (Tx) wavelengths of the mating converter. For example, an 8310-1 must be connected to an 8311-1.

Page 5

TECHNICAL SUPPORT:

For help with this product, contact our Technical Support:

Phone:

(949) 250-6510

Fax:

(949) 250-6514

Address: Omnitron Systems Technology, Inc.

 

140 Technology Dr., #500

 

Irvine, CA 92618 USA

E-mail:

support@omnitron-systems.com

URL:

www.omnitron-systems.com

Page 6

Page 7

Page 8

Page 9

Page 10 040-08300-001J 9/07

Page 1
Image 1
Omnitron Systems Technology specifications 10FL/T Specifications, About this Manual, Overview, Link Modes