Omnitron Systems Technology Gx AN SW4 and SW5 - Port 2 Pause Advertisement “OFF PAUSE” “OFF ASYM”

Models: Gx AN

1 2
Download 2 pages 59.22 Kb
Page 2
Image 2

Switch

 

 

 

Down

Up

 

 

 

 

 

(Factory Default)

 

SW1

 

P1 AN:

P1 MAN:

 

 

 

Port 1

Port 1

 

 

 

Fiber Auto-Negotiation

Fiber Manual Negotiation

SW2

 

P2 AN:

P2 MAN:

 

 

 

Port 2

Port 2

 

 

 

UTP Auto-Negotiation

UTP Manual

SW3

 

FDX:

 

HDX:

 

 

 

Port 2

Port 2

 

 

 

UTP Full-Duplex

UTP Half-Duplex

SW4

 

OFF:

 

PAUSE:

 

 

 

Port 2

Port 2

 

 

 

Pause Advertisement Enable

Pause Disable

SW5

 

OFF:

 

ASYM:

 

 

 

Port 2

Port 2

 

 

 

Asymmetric Pause

Asymmetric Pause Not

 

 

 

Advertised

Advertised

SW6 - SW8

 

 

See Link Mode Table

 

 

 

 

 

 

 

 

 

 

 

 

Figure B: DIP-Switches

 

 

 

 

 

SW2

 

SW3

 

Port 2 (UTP) Modes of Operation

 

 

 

 

 

AN

 

FDX

 

Configured for Auto-Negotiation.

 

 

 

 

 

It advertises and negotiates in this order:

 

 

 

 

 

1000FDX, 1000HDX

 

 

 

 

 

 

AN

 

HDX

 

Configured for Auto-Negotiation.

 

 

 

 

 

It advertises and negotiates:

 

 

 

 

 

1000HDX

 

 

 

 

 

 

MAN

 

FDX

 

Configured for Forced-Negotiation.

 

 

 

 

 

It advertises and negotiates:

 

 

 

 

 

1000FDX

 

 

 

 

 

 

MAN

 

HDX

 

Configured for Forced-Negotiation.

 

 

 

 

 

It advertises and negotiates:

 

 

 

 

 

1000HDX

 

 

 

 

 

 

 

 

Figure C: Port 2 (UTP) Modes

SW4 and SW5 - Port 2 Pause Advertisement “OFF PAUSE” “OFF ASYM”

These DIP-switches are only valid when Port 1 is set to “MAN”. The PAUSE modes will be based on the configuration of DIP-switches SW4 and SW5.

SW4

SW5

Port 2 (UTP) PAUSE Modes

 

 

 

OFF

OFF

No Pause advertised

 

 

 

OFF

ASYM

Asymmetric PAUSE towards link partner

 

 

 

PAUSE

OFF

Symmetric PAUSE

 

 

 

PAUSE

ASYM

Both Symmetric PAUSE and Asymmetric PAUSE

 

 

toward local device

 

 

 

Figure D: Pause Modes

SW6, SW7, SW8 - Link Modes

These three DIP-switches configure the link mode settings. DIP-switch SW6 is valid when Port 1 is set to “AN” or “MAN”. DIP-switches SW7 and SW8 are ignored when Port 1 is set to “AN”. The following table details possible Link Mode DIP-switch configurations.

SW1

SW6

SW7

SW8

Result

 

 

 

 

 

Down

Down

Down

Down

Enables Link Segment mode (LS).

(AN)

 

 

 

 

Down

Up

Down

Down

Enables Link Propagate mode (LP).

(AN)

 

 

 

 

Up

Down

Down

Down

Enables Link Segment mode (LS).

(MAN)

 

 

 

 

Up

Up

Down

Down

Enables Link Propagate mode (LP).

(MAN)

 

 

 

 

Up

 

 

 

Enables Remote Fault Detection

Down

Up

Down

mode plus Link Segment mode

(MAN)

 

 

 

(RFD+LS).

 

 

 

 

 

 

 

 

 

Up

Up

Up

Down

Enables Remote Fault Detection

mode plus Link Propagation mode

(MAN)

 

 

 

(RFD+LP).

 

 

 

 

 

 

 

 

 

Up

Down

Down

Up

Enables Symmetrical Fault Detect

(MAN)

mode (SFD).

 

 

 

 

 

 

 

 

Up

Up

Down

Up

Illegal Setting, Link Segment (LS) is

(MAN)

selected.

 

 

 

 

 

 

 

 

Up

Down

Up

Up

llegal Setting, Link Segment (LS) is

(MAN)

selected.

 

 

 

 

 

 

 

 

Up

Up

Up

Up

llegal Setting, Link Segment (LS) is

(MAN)

selected.

 

 

 

 

 

 

 

 

Figure E: Link Mode Table

NOTE: Connecting two converters set to any of the RFD modes is illegal and will cause a “deadly embrace” lockup.

NOTE: It is recommended to keep the LS setting (default) until initial configuration is complete.

For detailed information on the operation of the different Link Modes, download the application note “iConverter Link Modes” available on Omnitron’s web page:

http://www.omnitron-systems.com/downloads.php

2) SET-UP MODULE AND CONNECT CABLES

a.The Gx AN is available in tabletop and wall-mounting models. For wall-mounting, attach the unit to a wall, backboard or other flat surfaces. For tabletop installations, place the unit on a flat level surface. Attach the rubber feet to the bottom of the unit to prevent the unit from sliding. Make sure the unit is placed in a safe, dry and secure location.

To power the unit using the AC/DC adapter, connect the AC/DC adapter to the AC outlet. Then connect the barrel plug at the end of the wire on the AC/DC adapter to the 2.5mm DC barrel connector (center-positive) on the chassis. Confirm that the unit has powered up properly by checking the power status LED located on the front of the unit.