Sony 2008H05-1 service manual SCD-XA5400ES, Checking Emergency History, Procedure, A. Error code

Models: SCD-XA5400ES

1 66
Download 66 pages 54.55 Kb
Page 15
Image 15
4. Checking Emergency History

7.Press the [O RETURN] button on the remote commander to return to previous menu.

8.Press the [0] button on the remote commander to return to the top menu of Remocon Diagnosis Menu.

9.Disconnect the power cord to turn off.

Note: Don't press the [?/1] button when to release from this mode. Necessarily disconnect the power cord. The set doesn't operate when turning off power with [?/1] button of the set.

4. Checking Emergency History

To check the emergency history, please follow the following pro- cedure.

Procedure:

1.From the top menu of Remocon Diagnosis Menu, select “3. Emergency History” by pressing the [3] button on the remote commander. The following screen appears on the on-screen display.

 

 

 

Emg. History Check

 

Laser Hours

 

CD

999h

59min

 

 

 

 

 

DVD

999h

59min

01.

01

05

04

04

 

00

92

46

00

 

00

00

00

00

 

00

00

23

45

02.

02

02

01

01

 

00

A9

4B

00

 

00

00

00

00

 

00

00

23

45

[Next]Next page

[Prev]Prev page

[0]Return to Top Menu

 

 

 

 

2.You can check the total time when the laser is turned on during playback of super audio CD and CD from the above menu. The maximum time, which can be displayed are 999h 59min.

3.You can check the error code of latest 10 emergency history from the above menu. To view the previous or next page of emergency history, press the [.] or [>] button on the re- mote commander. The error code consists of three kinds of error codes.

A. Error code

Example of Error code

01.

01

05

04

04

00 92 46

00

 

00

00

00

00

00 00 23

45

The meaning of error code is as below:

01:Communication error (No reply from syscon)

02:Syscon hung up

03:Power OFF request when syscon hung up

19:Thermal shutdown

24:MoveSledHome error

25:Mechanical move error (5 changer)

26:Mechanical move stack error

30:DC motor adjustment error

31:DPD offset adjustment error

32:TE balance adjustment error

33. TE sensor adjustment error

34. TE loop gain adjustment error

35. FE loop gain adjustment error

36. Bad jitter after adjustment

40. Focus NG

42. Focus layer jump NG

51:Spindle stop error

SCD-XA5400ES

52.Open kick spindle error 60: Focus on error

61: Seek fail error

62: Read Q data/ID error

70: Lead in data read fail

71: TOC read time out (CD)

80: Can’t buffering

81: Unknown media type

B. Parameter of error code

This is the detail of error code.

Example of Error code

01. 01

05 04 04

00 92 46 00

 

 

 

 

23 45

00

00 00 00

00 00

C. Time of error code

This is the laser time when an error occurred.

Example of Error code

01. 01 05 04 04

00 92 46 00

00 00 00 00

00 00

23 45

To Clear the Laser Hour

Press the [DISPLAY] button on the remote commander and then press the [CLEAR] button on the remote commander. The data for both super audio CD and CD data are reset.

 

Emg. History Check

Laser Hours

CD

 

0h

0min

 

 

DVD

 

0h

0min

01.

01 05 04 04

 

00

92

46 00

 

00 00 00 00

 

00

00

23 45

02.

02 02 01 01

 

00

A9

4B 00

 

00 00 00 00

 

00

00

23 45

[Next]Next page

[Prev]Prev page

[0]Return to Top Menu

 

 

 

To Clear the Emergency History

Press the [TOP MENU] button on the remote commander and then press the [CLEAR] button on the remote commander. The error code for all emergency history would be reset.

 

Emg. History Check

Laser Hours

CD

999h

59min

 

 

DVD

999h

59min

01.

00 00 00 00

 

00 00

00 00

 

00 00 00 00

 

00 00

00 00

02.

00 00 00 00

 

00 00

00 00

 

00 00 00 00

 

00 00

00 00

[Next]Next page

[Prev]Prev page

[0]Return to Top Menu

 

 

15

Page 15
Image 15
Sony 2008H05-1 SCD-XA5400ES, Checking Emergency History, Procedure, A. Error code, The meaning of error code is as below