To Execute the Initialize Setup Data

SCD-XA5400ES

To Execute the Initialize Setup Data

Procedure:

1.Press the [MENU] button on the remote commander and then press the [CLEAR] button on the remote commander. The fol- lowing screen appears on the on-screen display.

Emg. History Check

59min

Laser Hours

CD

999h

 

DVD

999h

59min

Initialize setup data...

[Next]Next page [Prev]Prev page [0]Return to Top Menu

2. The screen after a while returns to former display.

To Return to the Top Menu of Remocon Diagnosis Menu

Press the [0] button on the remote commander.

5. Checking Version Information

To check the version information, please follow the following pro- cedure.

Procedure:

1.From the top menu of Remocon Diagnosis Menu, select “4. Version Information” by pressing the [4] button on the remote commander. The following screen appears on the on-screen display.

Version information

Firm(Main): Ver. X.XXXX

Firm(Sub): XX.XX

RISC: XXXXXX

8032: XXXXXX

Audio DSP: XX.XX.XX.XX

Servo DSP: XX.XX.XX.XX

[0]Return to Top Menu

2.To return to the top menu of Remocon Diagnosis Menu, press the [0] on the remote commander.

SECTION 5

ELECTRICAL ADJUSTMENT

When the base unit is replaced, perform the adjustment and the measurement as shown below in this order.

EXECUTING IOP MEASUREMENT (See page 14)