HOW TO OPEN THE TRAY WHEN POWER SWITCH TURNS OFF

SCD-XA5400ES

HOW TO OPEN THE TRAY WHEN POWER SWITCH TURNS OFF

#

Pull out the tray

in the direction of arrow #.

"MAIN BOARD SERVICE POSITION

 Rotate the cam (66) with a tapering driver

in the direction of arrow ".

BOTTOM VIEW

cam (66)

MAIN BOARD SERVICE POSITION

In checking the MAIN board, prepare jig (extension cable J-2501-102-A: 1 mm Pitch, 13 cores, Length 300 mm).

MAIN board (CN1100)

AUDIO board (CN151)

connect jig (extension cable J-2501-102-A) to MAIN board (CN501, CN1100) and

AUDIO board (CN151, CN152).

AUDIO board (CN152)

insulator sheet

 

Note: insert the insulator sheet to prevent short.

MAIN board

 

(CN501)

PRECAUTION WHEN REMOVING OPTICAL PICK-UP BLOCK OR DMB-FIT BOARD

CAUTION

Be sure to execute a solder bridge as a measure against static electricity when removing the optical pick-up or

DMB-FIT board.BOTTOM VIEW (Otherwise, the OP block will be destroyed.)

mechanism deck