Image 38

Polling-related error messages

The following table describes polling-related error messages. These are logged in the i2 Adapter log file.

Notes:

1.In some cases, the connector logs a fatal error (log message type of

XRD_FATAL) so that e-mail notification can be triggered. For logging this error with the integration broker, you need to set the connector property LogAtInterchangeEnd to true.

2.E-mail notification will be sent only if the e-mail connector is configured.

Error description

Error type

Handling by i2 connector

 

 

 

Connection lost while polling

Fatal error

The connector detects the connection

 

 

error at the time of a poll call. It logs a

 

 

fatal error (log message type of

 

 

XRD_FATAL) and dumps the XML

 

 

message. Fatal error can trigger e-mail

 

 

notification. For logging this error

 

 

with the integration broker, you need

 

 

to set the connector property

 

 

LogAtInterchange to true and

 

 

continue with polling on other

 

 

operations that might be running on

 

 

instances that are active.

 

 

 

Not able to register an

Fatal error

With subsequent poll calls, the i2

operation with the CIS Agent

 

connector tries to re-register the

 

 

operations that could not be registered

 

 

with the previous poll call. In case

 

 

registering all the operations fail, we

 

 

assume that the CIS agent is down;

 

 

the connector returns

 

 

APPRESPONSETIMEOUT which shuts

 

 

down the i2 connector.

 

 

 

No metaobjects configured for

Error

The i2 connector always returns a

polling

 

FAIL after logging that the metaobjects

 

 

are not configured for polling.

 

 

 

Default value for the metadata

Error

For details on the default value

object attributes not set

 

attribute property, see Chapter 3,

 

 

“Understanding business objects for

 

 

the connector”, on page 11. The error

 

 

required information for polling was

 

 

not found for the specified metaobject

 

 

is logged and the processing continues

 

 

for other messages.

 

 

 

Not able to fetch the message

Error/SUCCESS

In case the poll call to the i2

from CIS Agent

 

application returns a null, or there are

 

 

no events for the operation, the

 

 

connector continues to poll for other

 

 

operations. In case an exception is

 

 

caught from any CIS Client API , an

 

 

error message containing the word

 

 

ERROR_PROCESSING_EVENT is

 

 

logged. The connector continues to

 

 

poll for other operations.

 

 

 

28Adapter for i2 User Guide

Page 38
Image 38
IBM WebSphere Business Integration Adapter manual Polling-related error messages, Error description, Error type