The default value is false.
OADMaxNumRetry
Specifies the maximum number of times that the OAD automatically attempts to restart the
The default value is 1000.
OADRetryTimeInterval
Specifies the number of minutes of the retry time interval that the OAD automatically attempts to restart the
The default is 10.
PollEndTime
Time to stop polling the event queue. The format is HH:MM, where HH represents
You must provide a valid value for this property. The default value is HH:MM, but must be changed.
PollFrequency
The amount of time between polling actions. Set PollFrequency to one of the following values:
vThe number of milliseconds between polling actions.
vThe word key, which causes the connector to poll only when you type the letter p in the connector’s Command Prompt window. Enter the word in lowercase.
vThe word no, which causes the connector not to poll. Enter the word in lowercase.
The default is 10000.
Important: Some connectors have restrictions on the use of this property. To determine whether a specific connector does, see the installing and configuring chapter of its adapter guide.
PollStartTime
The time to start polling the event queue. The format is HH:MM, where HH represents
You must provide a valid value for this property. The default value is HH:MM, but must be changed.
RequestQueue
The queue that is used by the integration broker to send business objects to the connector.
The default value is REQUESTQUEUE.
44Adapter for i2 User Guide