SW3 - DTE SET CLOCK (TXC) POLARITY

SW3 - DTE SET CLOCK (TXC) POLARITY

When this DIP-switch is in the Terminal Timing Clock “TTC” (default) position, the clock edge used to sample the data on the serial port is defined by the TIA/EIA-334-C specification. When the DIP-switch is in the Terminal Timing Clock Inverted “Inv” position, the data on the serial port is sampled on the inverted clock edge.

SW4 - LOOPBACK

When “L-LB” is selected, the serial port data signals are looped back to the attached device. At the same time, the fiber port is looped. If the module has Terminal Timing enabled (see DIP-SWITCH BANK 1), the clock signals are also looped back to the attached device.

Switch

Down

Up

 

 

 

SW1

DCE:

DTE:

 

DCE Interface enabled

DTE Interface enabled

SW2

RC:

Inv:

 

RXC Clock polarity normal

RXC Clock polarity inverted

SW3

TTC:

Inv:

 

TXC Clock polarity normal

TXC Clock polarity inverted

SW4

Norm:

L-LB:

 

Loopback disabled

Loopback enabled

Figure B: Front Panel DIP-Switches

DIP-SWITCH BANK 1

SW1 -TERMINAL TIMING

When this DIP-switch is in the “Off” (default) position, Terminal Timing is disabled. When this DIP-switch is in the “On” position, Terminal Timing is enabled. When Terminal Timing disabled, it uses the ‘Signal Element Timing’ clock (SET clock, circuit S, X.21 pin pair 6, 13) as supplied by the DCE device to time Transmit data (TXD) and Receive data (RXD). This is called Contra-directional Timing. When Terminal Timing is enabled, it uses ‘DTE Signal Element Timing’ clock (DTE SET clock, circuit X, X.21 pin pair 7,

14)as supplied by the DTE device to time TXD, and uses ‘Signal Element Timing’ clock to time RXD. This is called Co-directional Timing.

When Terminal Timing is used, both the local and remote modules must be set to use Terminal Timing, as well as the devices connected to each module. All four units must be in Terminal Timing Mode.

Switch

Down

Up

 

 

 

SW1

Off:

On:

 

Terminal Timing disabled

Terminal Timing enabled

SW2

Off:

On:

 

Reserved

Reserved

 

 

 

SW3

Off:

On:

 

Reserved

Reserved

SW4

Off:

On:

 

Reserved

Reserved

2) INSTALL STANDALONE MODULE AND CONNECT CABLES

a.The X21 Serial Media Converter is available in tabletop and wall-mounting models. For wall-mounting, attach the unit to a wall, backboard or other flat surfaces. For tabletop installations, place the unit on a flat level surface. Attach the rubber feet to the bottom of the unit to prevent the unit from sliding. Make sure the unit is placed in a safe, dry and secure location.

To power the unit using the AC/DC adapter, connect the AC/DC adapter to the AC outlet. Then connect the barrel plug at the end of the wire on the AC/DC adapter to the 2.5mm DC barrel connector (center-positive) on the chassis. Confirm that the unit has powered up properly by checking the power status LED located on the front of the unit.

To power the unit using a DC power source, prepare a power cable using a two- conductor insulated wire (not supplied) with a 14 AWG gauge minimum. Cut the power cable to the length required. Strip approximately 3/8 of an inch of insulation from the power cable wires. Connect the power cables to the standalone unit by fastening the stripped ends to the DC power connector.

Connect the power wires to the DC power source. The Power LED should indicate the presence of power.

WARNING: Note the wire colors used in making the positive and negative connections. Use the same color assignment for the connection at the DC power source.

NOTE: If mounting with a safety ground attachment, use the safety ground screw at the rear of the unit.

b.When using the SFP model (8859-0), insert the SFP Fiber transceiver into the Port 1 SFP receptacle on the X21 converter (see SFP Data Sheet 091-17000-001 for supported transceivers).

NOTE: The release latch of the SFP Fiber transceiver must be in the closed (up) position before insertion.

c.Connect the included adapter cable to the serial port on the X21 converter. Use the appropriate gender plug to attach the X.21 device.

d.Connect an appropriate multimode or single-mode fiber cable to the fiber port of the installed module. It is important to ensure that the transmit (TX) is attached to the receive side of the device at the other end and the receive (RX) is attached to the transmit side. Single-fiber (SF) media converter models operate in pairs. The TX wavelength must match the RX wavelength at the other end and the RX wavelength must match the TX wavelength at the other end.

SERIAL PORT CONNECTOR

The serial port is a DE-15 female connector with the following pin-out configuration.

5

4

3

2

1

10 9 8 7 6

15 14 13 12 11

Figure C: Side DIP-Switches

Figure D: Serial Port Connector Pin-out for X.21 and RS-530

 