| Interchange | Direction |
| ||
PIN | Signal Name | Circuit |
|
|
| Notes |
|
| (AKA) | DTE |
| DCE |
|
|
|
|
|
|
|
|
11 | Transmit + | T | IN |
| OUT |
|
01 | Transmit - | (TXD) |
|
| ||
|
|
|
| |||
02 | Control + | C | IN |
| OUT |
|
07 | Control - | (RTS) |
|
| ||
|
|
|
| |||
08 | Receive + | R | OUT |
| IN |
|
12 | Receive - | (RXD) |
|
| ||
|
|
|
| |||
13 | Indication + | I | OUT |
| IN |
|
03 | Indication - | (CTS) |
|
| ||
|
|
|
| |||
04 | Signal Element Timing + | S | OUT |
| IN |
|
09 | Signal Element Timing - | (RXC) |
|
| ||
|
|
|
| |||
10 | DTE Signal Element Timing + | X | IN |
| OUT |
|
14 | DTE Signal Element Timing - | (TXC) |
|
| ||
|
|
|
| |||
06 | Shield Ground | Sheild | N/A |
| Connect to Chassis Ground | |
|
|
|
|
|
|
|
15 | Signal Ground | G | N/A |
| Connect to Logic Ground | |
| (GND) |
| ||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
05 | N/A |
|
|
|
| Spare Pin |
|
|
|
|
|
|
|
Figure E: Serial Port Signal Definitions
3) VERIFY OPERATION
Once the module has been installed and configured per steps 1 and 2, verify the module is operational by viewing the LED indicators.
The Power LED indicates the module is receiving power.
The Fiber Optic link LED indicates the fiber optic connection has been established.
Verify the serial port is configured for the correct mode of operation. Check the DCE/ DTE and TD/RD LEDs.
LED Function | Color | OFF State | ON State | |
"Legend" | ||||
|
|
| ||
|
|
|
| |
Power | Green | No power | Module has power | |
"Pwr" | ||||
|
|
| ||
Fiber Optics |
|
| On: Fiber signal detected |
iConverter X21 Standalone Module USER MANUAL
The Omnitron iConverter® X21 is a serial to fiber media converter featuring several configuration modes enabling connection to a wide variety of X.21 and
The X21 supports standard DCE sourced timing and terminal timing modes. The included adapter cable accommodates different connector gender types. The X21 features local loopback on the serial and fiber ports to facilitate testing and installations.
INSTALLATION PROCEDURE
1)Configure
2)Install Standalone Module and Connect Cables
3)Verify Operation
1)CONFIGURE DIP-SWITCHES FRONT PANEL DIP-SWITCH
SW1 - DCE/DTE
When this
SW2 - SET CLOCK (RXC) POLARITY
"P1" | Green | No Fiber Link | Blinking: Activity | |
|
| |||
Fiber Optics | Amber | No error detected | Error detected on fiber | |
"Err" | (No clock or corrupted messages) | |||
|
| |||
Serial Port | Green | Not configured for | Configured for connection to a DCE device | |
"DCE" | ||||
|
|
| ||
Serial Port | Green | Not configured for | Configured for connection to a DTE device | |
"DTE" | ||||
|
|
| ||
Timming Mode | Green | No activity / No clock detected | Blinking: Activity | |
"TD/RD" | ||||
|
|
| ||
Loopback | Amber | Loopback/Test mode not | Blinking: Unit in loopback | |
"Local LB"" | enabled | |||
|
|
Figure F: LED Indicators
When this
Up
SW1 SW4
Bank 1
Up
Down
SW1 SW4
Front Panel
Down
Form
Omnitron Systems Technology * 140 Technology Dr. #500 * Irvine, CA 92618
949.250.6510 tel * 949.250.6514 fax *