| Type | |||||
|
|
|
|
|
|
|
Item | Model |
|
|
|
|
|
|
|
|
|
|
| |
Vibration resistance | Destruction: 10 to 150 Hz, | Destruction: 10 to 150 Hz, | ||||
|
| 3 directions |
|
|
| double amplitude, with 4 sweeps |
|
|
|
|
|
| of 8 min each in 3 directions |
|
|
|
| |||
Shock resistance | Destruction: 294 m/s2, 3 times each in 6 directions |
|
| |||
Ambient temperature | −10 to 55°C (with no icing) |
|
|
| ||
|
|
|
|
| ||
Ambient humidity | 35% to 85% (with no condensation) |
|
|
| ||
|
|
|
|
|
| |
Storage temperature | −25 to 65°C |
|
|
|
| |
|
|
|
|
|
| |
Degree of protection | IEC60529: IP40 |
|
|
|
| |
|
|
|
|
|
| |
Ground |
| Ground to 100 Ω or less. |
|
|
| |
|
|
|
|
|
|
|
Material |
| ABS resin (case) |
|
|
|
|
|
|
|
|
| ||
Cable length |
| Standard, 0.5 m with a dedicated connector (See note.) |
|
| ||
|
|
|
|
|
|
|
Weight |
| Approx. 170 g |
|
|
| Approx. 180 g |
|
|
|
|
|
|
|
Note: The connector is not waterproof. If there is a possibility that the connector may be exposed to water, keep it inside the control box. Be sure to use the connector together with the separately sold interface cable.
■Functions
V600-HAR91/-HAR81 (Read-only type)
Reads the
Write
Writes on the set address the
V600-HAM91/-HAM81 (Multi-functional type)
The amplifier has the following three basic functions.
Read
Reads the
Verify
Reads the
V600-HAR92 (Read-only type)
Reads the
■Interface Cable
Amplifier | Cable length | Interface Cable | |
|
|
| |
2 m | |||
(Connector: 20 pin) |
|
| |
5 m | |||
| |||
|
|
| |
| 10 m | ||
|
|
| |
2 m | |||
|
| ||
5 m | |||
(Connector: 26 pin) | |||
|
| ||
10 m | |||
| |||
|
|
|
Note: The interface cable connector is not waterproof. If there is a possibility that the connector may be exposed to water, keep it inside the control box. The maximum cable length is 10 m.
Intelligent Flag I/II | 3 |