Power Supply Voltage

Do not impose any voltage exceeding the rated voltage range. Doing so, or applying alternating current (100 VAC) may cause the product to explode or burn.

Load Short-circuiting

Do not short-circuit the load connected to the product or connect to the power supply. Doing so may cause the product to explode or burn.

Wiring

Avoid wiring mistakes such as incorrect polarity in the power supply. Wiring mistakes may cause the product to explode or burn.

Correct Use

Grounding

The FG line is provided for grounding to the earth. When using the Amplifier in an environment where it is exposed to large amounts of noise or if the V600-HA@91/-HA@81/-HA@92 Amplifier malfunctions, provide a Class-3 ground (ground resistance of 100 or less). Note that sharing the grounding wire with other equipment or grounding to the beam of a building will adversely affect the grounding effect.

V600-HA†91/81/92

Other equipment

OK

FG

Less than 100

 

V600-HA†91/81/92

Other equipment

NG

FG

Less than 100

Mounting

Amplifier Spacing

When installing V600-HA@91/V600-HA@81/V600-HA@92 Amplifi- ers in a row, provide a minimum space of 10 mm between Amplifiers in order to prevent them from being affected by the heat produced by each Amplifier.

10 mm min.

V600-HA†91/81/92

When housing the Amplifiers in a box, provide a fan or ventilation opening for radiating the heat.

When wiring power cables, which carry large current such as motor drive cables, near the V600-HA@91/81/92 Amplifiers, conduct neces- sary tests to make sure that the installation conditions are fully satis- fied.

I/O Interface Requirements

1.The TRG input must be 10 ms min.

2.The INHIBIT input must be 20 ms min.

3.Minimum of 5 ms is required as the transfer time of the Read/ Write Selection Input (W/R).

4.The read data output must be read after the Normal End Output is set to ON.

Connecting the Sensor

Hold the black part of the connector, line up the notch and push it in until it clicks.

Compatibility with the SRAM Memory Type Data Carrier

1.If the Data Carrier is stationary in the transmission area for a long time when using the V600-HA@91/81 in the AUTO mode, or when using the V600-HAR92, it will drastically reduce the battery life. Therefore, stop the oscillation in the sensor either by turning off the power of the V600-HA@91/81/92 Amplifier or by setting the Inhibit input to ON.

2.Use a Data Carrier that has the oscillation frequency of 530 kHz. Note that the following models manufactured before February 1991 cannot be used.

V600-D2KR01

V600-D2KR02

Precautions When Using the AUTO Mode

If transmitting to the Data Carrier while it is traveling under the AUTO mode, conduct tests to make sure that the travel speed and installa- tion conditions are fully satisfied.

10Intelligent Flag I/II V600-HA

Page 9
Image 9
Omron V600-HA specifications Correct Use

V600-HA specifications

The Omron V600-HA is a cutting-edge temperature controller designed to meet the rigorous demands of industrial applications. It integrates advanced technologies and robust features to provide precise and reliable temperature management, making it an invaluable asset across various sectors, including manufacturing, food processing, and HVAC systems.

One of the standout features of the V600-HA is its exceptional control capabilities. It utilizes a proprietary PID (Proportional, Integral, Derivative) algorithm that enables it to maintain stable temperature levels with minimal deviation. This level of precision is critical in applications where temperature fluctuations can lead to product quality issues or operational inefficiencies.

In terms of technology, the V600-HA is equipped with a dual-display LCD that provides users with clear visibility of the current temperature, setpoint, and operational status. The user interface is intuitive, allowing for easy navigation through various settings and parameters. This accessibility ensures that operators can quickly make adjustments as needed without extensive training.

The V600-HA also features advanced communication capabilities, including support for protocols like Modbus and Ethernet. This connectivity allows for seamless integration with existing control systems, enabling remote monitoring and control. By leveraging these communication protocols, businesses can enhance operational efficiency and data collection, critical for process optimization.

Moreover, the controller boasts flexible input options. It supports various types of thermocouples and RTDs (Resistance Temperature Detectors), allowing it to be used in a wide range of temperature measurement scenarios. This versatility makes the V600-HA an excellent choice for diverse applications across different industries.

Another key characteristic of the Omron V600-HA is its robust construction. Designed for durability, it can withstand challenging environments, including extreme temperatures and vibrations often found in industrial settings. This rugged design contributes to a longer lifespan and reduced maintenance costs, ultimately enhancing productivity.

Additionally, the V600-HA incorporates safety features such as output limit control and alarm functions. These features help to preemptively address potential issues, ensuring safe operation and minimizing the risk of equipment damage or product loss.

In conclusion, the Omron V600-HA temperature controller stands out for its precise control capabilities, user-friendly design, advanced communication technologies, and robust construction. These features make it a reliable solution for industries that require stringent temperature management, ultimately driving efficiency and quality in operations.