Omron ZJ-FA20 manual Ordering Information, Ratings and Specifications, Dimensions, Rotation Range

Models: ZJ-FA20

1 6
Download 6 pages 3.1 Kb
Page 5
Image 5
Ordering Information

Ordering Information

Ionizer

Model

ZJ-FA20

Accessories (sold separafely)

 

Model

Replacement Filter

ZJ9-FL120N1 (set of 10)

Replacement Discharger Electrode

ZJ9-NDT06FN1 (set of 6)

 

 

Ratings and Specifications

Ionizer

Item

Model

ZJ-FA20

Power supply voltage

24 VDC (See note 1.)

Current consumption

900 mA max. (input from included AC adapter)

Discharge voltage

±7 kV

Discharge method

Variable DC

Airflow (m3/min.)

 

1.4 to 2.3 m3/min (typical)

Ionization time (See note 2.)

1.2 s (0.8 s with no Filter)

Ion balance (See note 2.)

±10 V max.

Amount of generated ozone

0.01 ppm max. (measured at a distance of 50 mm from air outlet)

Indicators

 

High-voltage output lamp: ION (yellow),

 

Cleaning lamp: CLEANING (orange), Power lamp: POWER (green)

 

 

Main functions

 

Automatic ion balance adjustment, airflow adjustment,

 

manual ion balance adjustment

 

 

Ambient temperature range

Operating and storage: 0 to 50°C (with no icing or condensation)

Ambient humidity range

Operating: 35% to 65%, storage: 35% to 85% (with no condensation)

Weight (packed state)

Approx. 2.0 kg

Materials

 

Unit: ABS, Discharger: Tungsten, stand: SPCC

Accessories

 

Instruction sheet, AC adapter, warning labels (2 types),

 

FG connection cable (2 m)

 

 

 

 

 

AC Adapter (Provided: UIA336-24-JR01A-998 by UNIFIVE CO., LTD.)

Item

 

Input voltage

100 to 240 VAC, 50/60 Hz

Power consumption

AC240V: 115VA MAX

240 VAC: 115 VA max.

 

Output voltage

24 VDC

Output current

1.5 A max.

Ambient temperature range

0 to 40°C

Ambient humidity range

35% to 85% (with no condensation)

Weight

Approx. 175 g (excluding power cable)

Dimensions

43.8 X 28 X 95.9 (W X D X H) mm

 

 

*If an additional AC adapter is required, please contact your OMRON sales representative

Note 1: Be sure to use the included AC adapter for Ionizer operation.

Note 2: Typical default settings.

Measurement location and conditions: Center of air outlet at a distance of 300 mm, with maximum fan speed

Ionization time: The time required to lower the charge from ±1,000 V to ±100 V

Ion balance measurement time: 10 s

Dimensions

 

 

197.5

 

 

 

 

 

 

 

8.5

80

12

 

 

 

140

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting Hole Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

120°

200

 

 

 

 

 

 

 

 

 

220

 

Seven,

M5

 

 

 

 

 

 

 

 

 

120

149

 

 

 

 

 

 

 

 

 

 

 

 

 

50±0.2

 

 

 

 

 

 

 

 

 

 

 

 

 

15±0.2

 

 

 

 

 

 

 

 

 

 

 

 

 

100±0.2

 

 

165

 

 

 

 

 

 

4

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60°

75

 

 

60°

 

 

 

Rotation Range

 

 

 

 

 

 

 

 

 

 

5

 

.

 

 

 

dia

.

 

 

 

 

 

 

dia

 

5.

5

 

 

 

60°

 

 

 

5

 

 

 

 

 

 

 

 

 

.

 

 

Thee,

 

 

 

 

 

 

 

100

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dia.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Unit: mm)

60°

120°

5.5

Page 5
Image 5
Omron ZJ-FA20 Ordering Information, Ratings and Specifications, Mounting Hole Dimensions, Rotation Range, Unit mm