Please read all instructions before installing

RS-250

Universal Application Wall Switch

Vacancy Sensor

 

with Manual ON/OFF

 

 

Lens

 

 

 

 

Lighted Switch

 

 

 

 

ON/OFF button

SPECIFICATIONS

 

Voltage

120VAC, 60Hz

Load (Single Pole Circuit)

 

Incandescent or fluorescent

0-600 Watts

Fan motor

1/6 hp

Time Delay Adjustment

15 seconds to 30 minutes

Light Level Adjustment

10 fc to 150 fc

Environment

Residential Indoor use only

Operating Temperature

32° to 131°F (0° to 55°C)

Humidity

95% RH, non-condensing

Tools Needed

 

Insulated Screwdriver

 

Wire Strippers

 

Santa Clara, CA 95050

DESCRIPTION AND OPERATION

Installation Instructions

The RS-250 Universal Application Wall Switch Vacancy Sensor is designed to replace a standard light or fan switch. It is ideal for living and dining rooms, family rooms, bedrooms, bathrooms and any other indoor area in a residential space where occupancy sensor-based manual ON/OFF controls are desirable.

Like a standard switch, you press the ON/OFF button to turn the light or fan (controlled load) ON and OFF. Unlike a standard switch, the RS-250 automatically turns OFF the controlled load after the coverage area has been vacant for a period of time (Time Delay). If motion is detected within 30 seconds after it automatically turns OFF, the RS-250 automatically turns the load back ON.

While the sensor is factory preset as a Vacancy Sensor with manual ON operation, it can be adjusted to work as an Occupancy Sensor that turns the controlled load ON automatically upon detection of occupancy in the area.

Lighted Switch

To help you locate the RS-250 in a dark room, the amber LED illuminates the ON/OFF button while the controlled load is OFF. When the controlled load is ON, the LED is OFF.

Operating Modes

There are two operating modes to select from during set up:

MODE 1 Vacancy sensor (Manual-ON/OFF, Auto-OFF): The user must press the ON/OFF button to turn the load ON. The RS-250 keeps the load ON until no motion is detected for the selected time delay period (adjustable from 15 seconds to 30 minutes). There is a 30 second reset delay. If motion is detected during this time, the sensor turns the load back on automatically. After the reset delay time has elapsed, the ON/OFF button must be pressed to turn ON the load.

MODE 2 Occupancy sensor (Auto-ON/OFF with manual control and reset to auto after 5 minutes of vacancy): The load turns ON and OFF automatically based on occupancy detection. The RS-250 keeps the load ON until no motion is detected for the selected time delay period. If the load is turned OFF manually, automatic-ON is re-enabled when no motion is detected for 5 minutes. This prevents the load from being turned ON after it was deliberately turned OFF.

Call 888.817.0571 for Technical Support