Please read all instructions before installing
RS-250
Universal Application Wall Switch
Vacancy Sensor
| with Manual ON/OFF |
| | Lens |
| |
| | Lighted Switch |
| |
| | ON/OFF button |
SPECIFICATIONS | |
Voltage | 120VAC, 60Hz |
Load (Single Pole Circuit) | |
Incandescent or fluorescent | 0-600 Watts |
Fan motor | 1/6 hp |
Time Delay Adjustment | 15 seconds to 30 minutes |
Light Level Adjustment | 10 fc to 150 fc |
Environment | Residential Indoor use only |
Operating Temperature | 32° to 131°F (0° to 55°C) |
Humidity | 95% RH, non-condensing |
Tools Needed | |
Insulated Screwdriver | |
Wire Strippers | |
Santa Clara, CA 95050
DESCRIPTION AND OPERATION
Installation Instructions
The RS-250 Universal Application Wall Switch Vacancy Sensor is designed to replace a standard light or fan switch. It is ideal for living and dining rooms, family rooms, bedrooms, bathrooms and any other indoor area in a residential space where occupancy sensor-based manual ON/OFF controls are desirable.
Like a standard switch, you press the ON/OFF button to turn the light or fan (controlled load) ON and OFF. Unlike a standard switch, the RS-250 automatically turns OFF the controlled load after the coverage area has been vacant for a period of time (Time Delay). If motion is detected within 30 seconds after it automatically turns OFF, the RS-250 automatically turns the load back ON.
While the sensor is factory preset as a Vacancy Sensor with manual ON operation, it can be adjusted to work as an Occupancy Sensor that turns the controlled load ON automatically upon detection of occupancy in the area.
Lighted Switch
To help you locate the RS-250 in a dark room, the amber LED illuminates the ON/OFF button while the controlled load is OFF. When the controlled load is ON, the LED is OFF.
Operating Modes
There are two operating modes to select from during set up:
MODE 1 Vacancy sensor (Manual-ON/OFF, Auto-OFF): The user must press the ON/OFF button to turn the load ON. The RS-250 keeps the load ON until no motion is detected for the selected time delay period (adjustable from 15 seconds to 30 minutes). There is a 30 second reset delay. If motion is detected during this time, the sensor turns the load back on automatically. After the reset delay time has elapsed, the ON/OFF button must be pressed to turn ON the load.
MODE 2 Occupancy sensor (Auto-ON/OFF with manual control and reset to auto after 5 minutes of vacancy): The load turns ON and OFF automatically based on occupancy detection. The RS-250 keeps the load ON until no motion is detected for the selected time delay period. If the load is turned OFF manually, automatic-ON is re-enabled when no motion is detected for 5 minutes. This prevents the load from being turned ON after it was deliberately turned OFF.