Features
Interactive Standby UPS UPS Series Series
*Online double conversion design
*Pure sine wave output with less than 3% THD
*Fully digitized microprocessor control
*Power factor correction
*Selectable UPS output voltage
*High efficiency mode
*Cold start function (DC power on)
*Emergency power off function (EPO)
*Short circuit and overload protection
*Fax/Modem/LAN data line surge protection
*Advanced battery management (ABM)
*Automatic battery charging in UPS OFF mode
*Automatic diagnostics and battery
*Extended battery pack available
*Multilanguage LCD display
*RS232 and USB Communication ports, UPS monitoring software
Line
Line UPS Series |
On |
Front Panel
Rear Panel
Input
RS232 |
|
|
|
|
| Communication |
|
|
|
|
| ||
|
|
|
|
| ||
EPO | External | Port | ||||
| Battery |
| ||||
| Connector |
|
Specifications
Model Name
Topology
Number of Phase
INPUT
Maximum Capacity
Nominal Input Voltage
Input Voltage Regulation
Nominal Input Frequency
Input PFC
Input Short Protection
OUTPUT
Nominal Output Voltage
Output Voltage Regulation
Output T.H.D
High Efficiency Mode (AC to AC)
Crest Factor
Start on Battery
Auto Restart
PROTECTION
Data Line Surge Protection
BATTERY
User Replaceable Batteries
Typical Backup Time (Full / Half load) Recharge Time to 90% Connected Battery Pack
ADVANCED WARNINGS / DIAGNOSTICS
Front Panel LEDs |
|
Audible Alarms |
|
COMMUNICATION INTERFACE |
|
Communication Port |
|
SNMP Manageable |
|
ENVIRONMENTAL |
|
Operation Temperature |
|
Storage Temperature |
|
Relative Humidity |
|
Audible Noise |
|
PHYSICAL |
|
Dimensions (Physical / Packing) | (in) |
(LxWxH) | (mm) |
Weight (Net / Gross) | (lbs) |
| (kg) |
Battery Pack (Net / Gross) | (kg) |
Battery Pack Dimensions | (in) |
| (mm) |
CONFORMANCE |
|
EMI / RFI Compatibility |
|
Safety Certifications |
|
windows
2000 / XP
2003 / Vista
DS10KB-RM
True
Pure Sine Wave
Single Phase (2W+G)
10000VA/7000W
208/220/230/240Vac
>0.97@Full load Circuit Breaker
208/220/230/240Vac (selectable)
Rated Voltage
<3% T.H.D at Linear Load
>92%
3 : 1
Yes Yes
RJ11 / RJ45
240V / 12V34W × 20 (in Battery pack)
12/24 min <4 Hours
AC mode / On line / On battery / Bypass / Fault / Overload and 15 UPS Parameters
Battery mode / UPS faults / Overload
RS232 and USB Port
Yes
0~40°C / 32~104°F
0~95% humidity,
<40dBA (at 1 meter from surface of unit)
23.5×16.9×5.1 / 29.1×22×10.7 597×428×130 / 740×560×273
44.1/ 52.9
20 / 24
66 / 75.5
23.5×16.9×5.1 / 29.1×22×10.7 597×428×130 / 740×560×273
CE; GOST-R
Sine Wave