DS10KB-RM

* DS10KB-RM

 

 

Features

Interactive Standby UPS UPS Series Series

*Online double conversion design

*Pure sine wave output with less than 3% THD

*Fully digitized microprocessor control

*Power factor correction

*Selectable UPS output voltage

*High efficiency mode

*Cold start function (DC power on)

*Emergency power off function (EPO)

*Short circuit and overload protection

*Fax/Modem/LAN data line surge protection

*Advanced battery management (ABM)

*Automatic battery charging in UPS OFF mode

*Automatic diagnostics and battery check-up

*Extended battery pack available

*Multilanguage LCD display

*RS232 and USB Communication ports, UPS monitoring software

Line

Line UPS Series

On

Front Panel

DS10KB-RM

Rear Panel

DS10KB-RM

Input

RS232

 

 

 

 

 

Communication

 

 

 

 

 

 

 

 

 

 

EPO

External

Port

 

Battery

 

 

Connector

 

Specifications

Model Name

Topology

On-battery Output Waveform

Number of Phase

INPUT

Maximum Capacity

Nominal Input Voltage

Input Voltage Regulation

Nominal Input Frequency

Input PFC

Input Short Protection

OUTPUT

Nominal Output Voltage

Output Voltage Regulation

Output T.H.D

High Efficiency Mode (AC to AC)

Crest Factor

Start on Battery

Auto Restart

PROTECTION

Data Line Surge Protection

BATTERY

User Replaceable Batteries

Typical Backup Time (Full / Half load) Recharge Time to 90% Connected Battery Pack

ADVANCED WARNINGS / DIAGNOSTICS

Front Panel LEDs

 

Audible Alarms

 

COMMUNICATION INTERFACE

 

Communication Port

 

SNMP Manageable

 

ENVIRONMENTAL

 

Operation Temperature

 

Storage Temperature

 

Relative Humidity

 

Audible Noise

 

PHYSICAL

 

Dimensions (Physical / Packing)

(in)

(LxWxH)

(mm)

Weight (Net / Gross)

(lbs)

 

(kg)

Battery Pack (Net / Gross)

(kg)

Battery Pack Dimensions

(in)

 

(mm)

CONFORMANCE

 

EMI / RFI Compatibility

 

Safety Certifications

 

windows

2000 / XP

2003 / Vista

DS10KB-RM

True On-Line, Double Conversion

Pure Sine Wave

Single Phase (2W+G)

10000VA/7000W

208/220/230/240Vac

176-276Vac 50Hz / 60Hz Auto Sensing

0.97@Full load Circuit Breaker

208/220/230/240Vac (selectable)

Rated Voltage +/-2%

3% T.H.D at Linear Load

92%

3 : 1

Yes Yes

RJ11 / RJ45

240V / 12V34W × 20 (in Battery pack)

12/24 min 4 Hours BP10000-RM

AC mode / On line / On battery / Bypass / Fault / Overload and 15 UPS Parameters

Battery mode / UPS faults / Overload

RS232 and USB Port

Yes

0~40°C / 32~104°F -20~60°C / -4~140°F

0~95% humidity, non-condensing

<40dBA (at 1 meter from surface of unit)

23.5×16.9×5.1 / 29.1×22×10.7 597×428×130 / 740×560×273

44.1/ 52.9

20 / 24

66 / 75.5

23.5×16.9×5.1 / 29.1×22×10.7 597×428×130 / 740×560×273

CE; GOST-R

C-Tick, A-Tick; GOST-R

Sine Wave

Networking Green Power Surge Series Inverter Series AVR Series Series Series

33.

Page 1
Image 1
OPTI-UPS DS10KB-RM specifications Input, Output, Protection, Battery, Advanced Warnings / Diagnostics, Environmental