Hardware Tests Diagnostics dialog box

A

Hardware Tests Diagnostics dialog box

The Port Tests diagnostics dialog box enables you to run tests on the port and to configure parameters such as link speed and frame count.

Opening the dialog box

1.Select an HBA or HBA port from the device tree.

2.Select Configure > Diagnostics from the Host Connectivity Manager.

3.Click the Hardware Tests tab.

Fields and components

Field

Description

 

 

Memory Test check box

Check to run a Memory test on the port.

 

 

Ports list

Select a port from the list.

 

 

PCI Loopback Test check box

Check to run a PCI Loopback test on the port.

 

 

Data Pattern

Type a data pattern. The default value is A5A5A5A5.

 

 

Test Cycle text box

Specify the number of times the test runs. The default value is 100.

 

 

Loopback Test check box

Check to run a Loopback test on the port.

 

 

Queue Test check box

Check to run a Queue test on the port.

 

 

Subtest ID list

Select a subtest from the list. The default is Internal.

 

 

Link Speed list

Select a link speed from the list.

 

 

Frame Count

Type a frame count. The default value is 8192.

 

 

Stop on Error check box

Check to flag the system to stop running the test if an error occurs.

 

 

Test Log table

Displays the time the test was run, the status of the test, and the

 

result of the test.

 

 

Start button

Click to run the selected test.

 

 

Stop button

Click to stop all pending tests.

 

 

Using the dialog box

Refer to the following topics for specific procedures using this dialog box:

“Configuring beaconing using HCM”

“supportSave collection sources”

Brocade Adapters Administrator’s Guide

85

53-1001583-01

 

Page 99
Image 99
Brocade Communications Systems 804 manual Hardware Tests Diagnostics dialog box, Click the Hardware Tests tab