Hardware Tests Diagnostics dialog box | A |
Hardware Tests Diagnostics dialog box
The Port Tests diagnostics dialog box enables you to run tests on the port and to configure parameters such as link speed and frame count.
Opening the dialog box
1.Select an HBA or HBA port from the device tree.
2.Select Configure > Diagnostics from the Host Connectivity Manager.
3.Click the Hardware Tests tab.
Fields and components
Field | Description |
|
|
Memory Test check box | Check to run a Memory test on the port. |
|
|
Ports list | Select a port from the list. |
|
|
PCI Loopback Test check box | Check to run a PCI Loopback test on the port. |
|
|
Data Pattern | Type a data pattern. The default value is A5A5A5A5. |
|
|
Test Cycle text box | Specify the number of times the test runs. The default value is 100. |
|
|
Loopback Test check box | Check to run a Loopback test on the port. |
|
|
Queue Test check box | Check to run a Queue test on the port. |
|
|
Subtest ID list | Select a subtest from the list. The default is Internal. |
|
|
Link Speed list | Select a link speed from the list. |
|
|
Frame Count | Type a frame count. The default value is 8192. |
|
|
Stop on Error check box | Check to flag the system to stop running the test if an error occurs. |
|
|
Test Log table | Displays the time the test was run, the status of the test, and the |
| result of the test. |
|
|
Start button | Click to run the selected test. |
|
|
Stop button | Click to stop all pending tests. |
|
|
Using the dialog box
Refer to the following topics for specific procedures using this dialog box:
•“Configuring beaconing using HCM”
•“supportSave collection sources”
Brocade Adapters Administrator’s Guide | 85 |
|