5 Diagnostics using HCM
3.Click the check box that corresponds to the port test you are running.
4.Specify the parameters based on parameter information found in Table 12.
NOTE
Click the Stop on Error check box if you want the test to stop running if an error occurs.
5.Click Start to run the test.
Hardware-level test parameters
TABLE 12 Hardware-level test parameters
| Parameter | Test Options |
|
|
|
Memory test | None | You can enable or disable this test. |
|
| Regardless of test cycle set value, the |
NOTE: During the test, IOC will |
| Memory Test will run only once. |
be disabled. |
|
|
|
|
|
PCI loopback test | Frame Count | Integer from 0 - 4,294,967,295. The |
|
| default value is 8192. |
|
|
|
| Data Pattern | Default value is A5A5A5A5. |
|
|
|
| Test Cycle | The number of times the test runs. The |
|
| default value is 10. |
Port loopback test
NOTE: For an External Loopback test, you must plug in the loopback connector.
For a Brocade 804 mezzanine card, a
Subtest ID | • | Internal |
| • | External |
| • | Serdes |
|
| |
Link Speed | 2, 4, and 8 Gbps | |
|
| |
Frame Count | Integer from 0 - 4,294,967,295. The | |
| default value is 8192. | |
|
| |
Test Cycle | The number of times the test runs. The | |
| default value is 10. |
| Data Pattern (hexadecimal) | Default value is A5A5A5A5. |
|
|
|
Queue test | You can enable or disable this | Queue number from |
| test. | only allows you to enable or disable the |
Sends a health check message |
| queue test (and not specify an integer), |
from host to firmware through |
| all the queues will be tested. |
message queues memory |
|
|
mapped over the PCI. |
|
|
|
|
|
56 | Brocade Adapters Administrator’s Guide |
|