5 Diagnostics using the BCU

diag commands

The diag commands shown in Table 10 monitor hardware components and can be performed while the system is running (they are non-disruptive). Refer to “diag” on page 137 for command details.

NOTE

The sfpshow and beacon commands are not applicable for Brocade 804 mezzanine cards.

TABLE 10

Fibre Channel diag commands

 

 

Command

Description

 

 

beacon

Blinks the appropriate port LED for physical identification. Beaconing can

 

occur at the port or the link level.

 

End-to-end (E2E) beaconing is a software feature that can be enabled on

 

Brocade 8 Gbps HBAs to allow the local HBA to flash (beacon) and also

 

cause the connected Fibre Channel switch port to uniquely beacon. Refer

 

to the Brocade Adapters Installation and Reference Guide for details on

 

E2E beaconing patterns.

 

 

loopback

Tests the data path from the IOC to the desired network loopback port

 

(internal, serdes, external) and back. This is an offline diagnostic test.

 

 

memtest

Tests the adapter’s memory blocks.

 

 

pciloopback

Checks the communications path between the host and the IO Controller

 

(IOC).

 

 

queuetest

Tests the CPE/RME queue.

 

 

sfpshow

Displays small form factor pluggable (SFP) information.

 

 

tempshow

Displays the temperature of the adapter.

 

 

fcdiag commands

Fibre Channel diagnostics include the tests shown in Table 11. Refer to “fcdiag” on page 141 for details about this command.

TABLE 11

Fibre Channel diagnostic tests

 

 

Command

Description

 

 

fcping

Determines the basic connectivity between the Fibre Channel

 

network points and monitors and measures network latency.

 

 

fctraceroute

Reports on a SAN path, including node hops and latency data.

 

 

fcecho

Sends an FC Echo Extended Link Services (ELS) request to a remote

 

port.

 

 

linkbeacon

Blinks the LED light of the remote port of the link.

 

 

scsitest

Tests the SCSI components.

 

 

54

Brocade Adapters Administrator’s Guide

 

53-1001583-01

Page 68
Image 68
Brocade Communications Systems 804 manual Diag commands, Fcdiag commands