5 Diagnostics using the BCU
diag commands
The diag commands shown in Table 10 monitor hardware components and can be performed while the system is running (they are
NOTE
The sfpshow and beacon commands are not applicable for Brocade 804 mezzanine cards.
TABLE 10 | Fibre Channel diag commands |
|
|
Command | Description |
|
|
beacon | Blinks the appropriate port LED for physical identification. Beaconing can |
| occur at the port or the link level. |
| |
| Brocade 8 Gbps HBAs to allow the local HBA to flash (beacon) and also |
| cause the connected Fibre Channel switch port to uniquely beacon. Refer |
| to the Brocade Adapters Installation and Reference Guide for details on |
| E2E beaconing patterns. |
|
|
loopback | Tests the data path from the IOC to the desired network loopback port |
| (internal, serdes, external) and back. This is an offline diagnostic test. |
|
|
memtest | Tests the adapter’s memory blocks. |
|
|
pciloopback | Checks the communications path between the host and the IO Controller |
| (IOC). |
|
|
queuetest | Tests the CPE/RME queue. |
|
|
sfpshow | Displays small form factor pluggable (SFP) information. |
|
|
tempshow | Displays the temperature of the adapter. |
|
|
fcdiag commands
Fibre Channel diagnostics include the tests shown in Table 11. Refer to “fcdiag” on page 141 for details about this command.
TABLE 11 | Fibre Channel diagnostic tests |
|
|
Command | Description |
|
|
fcping | Determines the basic connectivity between the Fibre Channel |
| network points and monitors and measures network latency. |
|
|
fctraceroute | Reports on a SAN path, including node hops and latency data. |
|
|
fcecho | Sends an FC Echo Extended Link Services (ELS) request to a remote |
| port. |
|
|
linkbeacon | Blinks the LED light of the remote port of the link. |
|
|
scsitest | Tests the SCSI components. |
|
|
54 | Brocade Adapters Administrator’s Guide |
|