Brocade Communications Systems 804 manual Running a Fibre Channel protocol-level test using HCM

Models: 804

1 186
Download 186 pages 14.89 Kb
Page 71
Image 71

Diagnostics using HCM

5

Running a Fibre Channel protocol-level test using HCM

There are three protocol-level tests:

Echo test, which sends an FC Echo ELS to a remote port.

FC ping test, which requests the management server to test the connectivity with a given remote port (without zoning restrictions). Not supported in Solaris operating systems.

FC traceroute test, which requests to enumerate the route between two given end points. Not supported in Solaris operating systems.

To run one of the protocol-level tests, use the following procedure.

1.Select an adapter or port from the device tree.

2.Select Configure > Diagnostics from the main menu.

OR

Right-click the component and select Diagnostics from the list. The Diagnostics dialog box, shown in Figure 22, displays.

3.Click the FC Protocol Tests tab.

FIGURE 22 Protocol-level diagnostic tests dialog box

Brocade Adapters Administrator’s Guide

57

53-1001583-01

 

Page 71
Image 71
Brocade Communications Systems 804 Running a Fibre Channel protocol-level test using HCM, Click the FC Protocol Tests tab