June
Brocade Adapters
Brocade Communications Systems, Incorporated
Contents
Chapter Host Configuration
Chapter Monitoring
Appendix B Brocade Command Utility
Appendix C HCM Troubleshooting
Viii Brocade Adapters Administrator’s Guide 53-1001583-01
How this document is organized
This section
Italic text
Document conventions
Text formatting
Bold text
Key terms
Additional information
Brocade resources
Related documentation
Getting technical help
Other industry resources
Documentation@brocade.com
Document feedback
Xiv Brocade Adapters Administrator’s Guide 53-1001583-01
Host bus adapters
This chapter
HCM software
HCM features
Tree node pop-up menus
SAN component Pop-up menu feature
Adapter operating system support
Adapter support
Launching the application on Windows platforms
HCM software launch
Launching the application on Linux platforms
Remember password
Skip login
Changing an HCM application password
Changing an HCM agent password
Change HCM Agent Password dialog box, shown in , displays
Downgrading driver only
Software downgrade using Adapter Software Installer
HCM configuration data
Downgrading HCM and driver or HCM only
Data restoration
Backing up data after an uninstall
Restoring backed up data
Click Start Restore
Host Connectivity Manager main window
HCM main window
LUN
HCM product icons
Event severity icons
Discovery
Setting up out-of-band discovery for an adapter
Logging off HCM
Configuring security authentication using HCM Host and HBA
Host security authentication
Brocade Adapters Administrator’s Guide
Bcu auth --algoportid mdsha1mssm
Configuring security authentication using the BCU
Bcu auth --secretportid secretstring
Configurable using
Basic port configuration
Buffer credits
Port logging level
Opening the Basic Port Configuration dialog box
Port speed
Configuring the port logging level using HCM
Configuring the port logging level using the BCU
Configuring the port speed using HCM
Frame data field size
Configuring the port speed using the BCU
Specifying the maximum frame size using HCM
Configuring the frame data field size using the BCU
Enabling and disabling persistent binding using the BCU
Enabling and disabling persistent binding using HCM
Persistent binding
Configuring QoS on the HBA side using the BCU
Configuring QoS on the switch side using the BCU
QoS
Target rate limiting
Specifying path time out using HCM
Specifying path time out using the BCU
Path time out
Basic port configuration
Configuring Boot over SAN
Boot over SAN
Boot over SAN
Configuring fabric-based boot LUN discovery
Pre-boot configuration
Uploading the boot image using HCM
Boot image update
Updating the boot image using the BCU
Creating a virtual port
Virtual port configuration
Select Configure Virtual Port Create from the main menu
Virtual port restrictions
Deleting a virtual port
Select Configure Virtual Port Delete from the main menu
HCM logging levels
Configuring the HCM logging level using HCM
Opening the Advanced Port Configuration dialog box
Advanced port configuration
Interrupt Control Coalesce
Configuring the Interrupt Control Coalesce using HCM
Select On from the Interrupt Control Coalesce list
Dual role changes
Name configuration
Name validation
Editing the name fields
Defining a name
Adding name entries
Exporting the properties for a WWN
Removing a name entry
Importing the properties for a WWN
Importing properties in Dcfm or FM format
Importing properties in Efcm format
Importing duplicated names
Npiv
Performance monitoring
Monitoring
Polling frequency rate
Resetting statistics
Controlling the polling frequency rate
Master log
Severity column
Filter button
Clear Filter button
Sr No column
Filtering event log entries
HCM Application Log
Application log
Syslog support
Opening the Syslog Server Configuration dialog box
Registering a host server
Removing a host server
Syslog host configuration using VMware
Diagnostics using the BCU
Diagnostics
Fcdiag commands
Diag commands
Running a hardware-level test using HCM
Diagnostics using HCM
Hardware-level test parameters
Hardware-level test parameters
Click the FC Protocol Tests tab
Running a Fibre Channel protocol-level test using HCM
Test Log Details for Echo Test dialog box
Displaying test log details
Configuring beaconing using the BCU
Configuring beaconing using HCM
Beaconing
Displaying SFP information using HCM
Displaying SFP information using the BCU
SFP management
Portlogclear
Debugging
SupportSave
Portlog
Automatic statistics collection
SupportSave collection sources
SupportSave collection using a command prompt
SupportSave collection using HCM
SupportSave collection on a port crash event
SupportSave collection using a browser
This appendix
HCM Dialog Boxes
This appendix
Opening the dialog box
Authentication Statistics dialog box
Fields and components
Using the dialog box
Browse button
Backup dialog box
Start Backup button
Output Directory text box
Opening the properties panel
Base Port Properties panel
Using the dialog box
Change HCM Password dialog box
Change HCM Agent Password dialog box
Configure Names dialog box
Using the dialog box
World wide name for the device
Define Name dialog box
Names button
User/Administrator will manually fix
Duplicated Names dialog box
Append unique suffix for all repetitive
Event Properties dialog box
Fabric Statistics dialog box
FCP IM Statistics dialog box
HAL TM Successes
HAL TM Related IO Cleanups
HAL TM Offline Cleanup Completions
HAL TM Firmware Responses
FCP IM Module Statistics dialog box
IO comp with unknown tags
IO aborted due to TM commands
IO implicitly aborted
Fibre Channel Security Protocol Configuration dialog box
Apply button
Group list
Click the Hardware Tests tab
Hardware Tests Diagnostics dialog box
HBA Properties panel
EC level
Current # of Lanes
Initial Negotiated # of Lanes
PCIe Generation
IOC Statistics dialog box
Firmware IO error REC
Firmware IO xferrdy000 error
Firmware IO xferrdyunknownerror
Firmware IO ITN Sler initiated Firmware IO REC timeouts
Firmware Port FPG Sync Timeout
Firmware IO IOH Error Interrupt
Firmware Port FPG Signal Lost
Firmware Port FPG Signal Regained
Firmware Port Snsm Error Resets
Firmware Port Physm Laser Faults
Firmware Port Snsm Hwsm Timeouts
Firmware Port Snsm Swsm Timeouts
Firmware Port Lksm OLS TX Started
Firmware Port Lksm LR TX Started
Firmware Port Lksm LRR TX Started
Firmware Port Lksm NOS TX Started
Logical Port Statistics dialog box
Nsgidftsent
MS command retries
MS command timeouts
Nsrftidallocwait
Lport Properties panel
Refresh button
Using the Master Log
Master Log tab
Opening the Master Log
Event Time
Master Log Filter dialog box
Event Severity
Persistent Binding dialog box
Select Configure Persistent Binding
Operating Speed
Port Properties panel
Using the property panel
Port Statistics dialog box
Rx CRC err good EOF frames
Errored frames
Loss Of signal count
Rx CRC err frames
Protocol Tests dialog box
QoS Statistics dialog box
Remote Port Properties panel
Start Restore button
Restore dialog box
Restore from previous backup data
Restore default data button
Speed
SFP Properties panel
Vendor Part
Length Cu
Vendor Name
Vendor OUI
Host name / IP Address text box
Syslog Server Configuration dialog box
Target Statistics dialog box
Rpsc sent
Logo received
Rpsc received
Rpsc rejects
Offline online events
Fw delete IOC down events
Fw delete exception events
Offline delete events
Brocade Adapters Administrator’s Guide 113 53-1001583-01
Result
Configuration
Test Log Details dialog box
Test
Virtual Port Creation dialog box
Delete Selected button
Cancel button
Virtual Port Deletion dialog box
Deletion check box
Virtual Port Properties panel
Preboot Created
Base Port
Virtual Port Statistics dialog box
Brocade Adapters Administrator’s Guide 119 53-1001583-01
120 Brocade Adapters Administrator’s Guide 53-1001583-01
Brocade Command Utility
About the BCU
BCU commands
Bios commands
Controller IOC commands Networking
Target persistent binding commands
Adapter
See Also
Example
Auth
Stats
Show
Statsclr
See Also None
Synopsis bcu bios --query portid
Bios
Operands Query
Pwwn,lun
Update
Boot
Operands BlunZone
Bios
Portlog portid
Debug
Operands Portlog
HAL