8.3.3.Tilt Angle

Opticon

OPL 9712

Specifications Manual

8.3.3.Tilt Angle

Scanning performance is guaranteed when γ = ±20°

°

0 2 = γ

°

0

2

= γ

Figure 6: Tilt angle

Conditions

Barcode Sample: OPTOELECTRONICS Test Sample

Distance:

90 mm from the edge of the data collector

 

 

Label:

Pitch, Skew Angle

 

PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39,

 

Quiet Zone = 10 mm, N/W Ratio = 1:2.5

 

Dead Zone, Tilt Angle

 

PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm

 

 

Angle:

Curvature: R = ∞, Skew Angle = β +15° (for measuring Pitch Angle and Tilt Angle)

 

 