8. Technical Specifications

The conditions for technical specifications are as follows, unless otherwise specified in each section.

Conditions

Ambient temperature and humidity

Room temperature (5–35° C) and room humidity

 

(45% RH–85% RH)

Ambient light

500 to 900 lx

Background

Barcode = black

 

Space = white

 

Margin = white

 

Background of label = black

8.1.Print Contrast Signal (PCS)

0.45or higher (over 70% of reflectivity of space and quiet zone).

PCS is determined by: Reflectance of white bar – Reflectance of black bar / Reflectance of white bar

8.2. Scan Area and Resolution

The depth of field is measured from the edge of the data collector. The scanning range is within the circular arc centered on the scan origin.

365

240

145

75

60

40 35

゚ 4 4

Reso lu t ion 0 .25

Reso lu t ion 0 .5

Reso lu t ion 1 .0

CLR

3DEF

6MNO

9WXYZ

ENT

52

2ABC

5 JKL

8TUV

 

BS

0 -

Sh ift

1

4GH I

7PQRS

.* ...

M inmumi read ing d is tance

Reso lu t ion 0 .15

Figure 3: The depth of field

The depth of field is measured from the front edge of the data collector.

9

Page 9
Image 9
Opticon OPL 9712 specifications Technical Specifications, Print Contrast Signal PCS, Scan Area and Resolution