Opticon OPL 9712 specifications Environmental Specifications, Operating Temperature and Humidity

Models: OPL 9712

1 27
Download 27 pages 32.13 Kb
Page 7
Image 7
4.Environmental Specifications

Opticon

OPL 9712

Specifications Manual

4.Environmental Specifications

4.1.Operating Temperature and Humidity

Temperature: 0 to 40° C

Humidity: 20 to 85%

4.2.Storage Temperature and Humidity

Temperature: -20 to +60° C

Humidity: 20 to 90%

4.3.Ambient Light Immunity

Decoding performance is guaranteed when the range of illumination on a barcode surface is between zero and the following values:

Incandescent light

3,000 lx

Fluorescent light

3,000 lx

Sunlight

50,000 lx

Figure 2: Ambient Light

Immunity

Conditions

Barcode Sample: OPTOELECTRONICS Test Sample

PCS:

0.9

Resolution:

0.25 mm

Symbology:

8-digit Code 39

Quiet Zone:

10 mm

N/W Ratio:

1:2.5

Direct light or specular reflection light from a source should be prevented from entering the acceptance area.

7

Page 7
Image 7
Opticon OPL 9712 Environmental Specifications, Operating Temperature and Humidity, Storage Temperature and Humidity