13. Durability

13.1. Electrical Noise

No malfunction should occur when sinusoidal electrical noise (10Hz -100kHz, < 0.1Vpp)

is added to a power supply line.

Conditions

Barcode Sample: OPTOELECTRONICS Test Sample

PCS: 0.9
Resolution: 0.25 mm
Symbology: 9-digit Code-39
Quiet Zone: 10 mm
N/W Ratio: 1:2.5
Distance: 100 mm from the edge of scanner
Angle: α = 0° β = 15° γ = 0°
Curvature: R =
Power Supply Voltage: 6.0 V (RS-232C) / 5.0 V (USB and Wedge)

13.2. Static Electricity

Air discharge: 8 kV max (No malfunction)
15 kV max (No destruction)
Contact discharge: 6 kV
Contact discharge at the hook and the screw
Measurement environment: Use electrostatic testing device compliant with IEC 61000-4-2
Discharge resistance: 330
Capacitor charging: 150 pF